Development of a hybrid cardiovascular graft using a tissue engineering approach

被引:101
作者
Tiwari, A
Salacinski, HJ
Punshon, G
Hamilton, G
Seifalian, AM
机构
[1] Royal Free Hosp, Univ Coll London, Royal Free & Univ Coll Med Sch, Univ Dept Surg, London NW3 2QG, England
[2] UCL, Royal Free & Univ Coll Med Sch, Univ Dept Surg, Tissue Engn Ctr, London, England
关键词
hybrid graft; anticoagulant peptide; endothelial cells; spacer arm; covalent bonding; x-ray photoelectron spectroscopy;
D O I
10.1096/fj.01-0826com
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Tissue engineering of endothelial cells (EC) and chemical engineering with anticoagulant moieties has been undertaken in order to improve prosthetic graft patency and thrombogenicity. This was done by covalently bonding a compliant poly(carbonate-urea) urethane graft (MyoLink(TM)) with arginine-glycine-aspartate (RGD) or/and heparin (Hep) to ascertain whether EC retention could be improved. The retention of these moieties and EC was assessed after exposure to pulsatile flow. We covalently bonded RGD, Hep, and RGD/Hep onto the luminal surface of MyoLink using spacer arm technology. Narrow-beam X-ray photoelectron spectroscopy was carried out to check the efficiency of the bonding. EC were radiolabeled and seeded onto native MyoLink and with 1) RGD-, 2) Hep-, and 3) RGD/Hep-bonded grafts and exposed to shear stress in a physiological flow circuit for 6 h, which reproduces femoral artery flow waveforms and pulsatility. Results were recorded on a gamma camera imaging system. Viability of cells was tested with a modified Alamar Blue assay (ABA) and scanning electron microscopy for morphological appearance of seeded cells. Experiments were repeated (n=6). RGD, Hep, and RGD/Hep were bonded together in a uniform distribution on the luminal surface of each graft type, and bioactivity of each moiety covalently bonded was very high. In the flow circuit, there was exponential cell retention for the first 60 min of flow for all the grafts, but after 6 h of exposure to pulsatile flow the RGD/Hep-bonded graft had a significantly better cell retention rate than native MyoLink (75.7%+/-2.3 vs. 60.5+/-10.1, P<0.05). ABA test showed that all the seeded cells postexposure to flow were viable, and significantly higher metabolic activity was recorded on a RGD/Hep-bonded graft than with MyoLink-seeded graft (P<0.01). Using RGD/Hep covalently bonded onto graft surfaces improves cell retention and provides an antithrombogenic surface for initial blood flow in vivo until full EC activity develops postseeding. This would allow the development and further improvement of hybrid grafts.
引用
收藏
页码:791 / 796
页数:6
相关论文
共 31 条
[1]   EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]   COVALENT ATTACHMENT OF AN ARG-GLY-ASP SEQUENCE PEPTIDE TO DERIVATIZABLE POLYACRYLAMIDE SURFACES - SUPPORT OF FIBROBLAST ADHESION AND LONG-TERM GROWTH [J].
BRANDLEY, BK ;
SCHNAAR, RL .
ANALYTICAL BIOCHEMISTRY, 1988, 172 (01) :270-278
[3]   Clinical autologous in vitro endothelialization of infrainguinal ePTFE grafts in 100 patients: A 9-year experience [J].
Deutsch, M ;
Meinhart, J ;
Fischlein, T ;
Preiss, P ;
Zilla, P .
SURGERY, 1999, 126 (05) :847-855
[4]   Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial [J].
Devine, C ;
McCollum, C .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :533-539
[5]   Effect of prolonged pulsatile shear stress in vitro on endothelial cell seeded PTFE and compliant polyurethane vascular grafts [J].
Giudiceandrea, A ;
Seifalian, AM ;
Krijgsman, B ;
Hamilton, G .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (02) :147-154
[6]  
Giudiceandrea A, 2000, J ARTIF ORGANS, V3, P16
[7]   IDENTIFICATION OF AN AMINO-ACID-SEQUENCE IN LAMININ MEDIATING CELL ATTACHMENT, CHEMOTAXIS, AND RECEPTOR-BINDING [J].
GRAF, J ;
IWAMOTO, Y ;
SASAKI, M ;
MARTIN, GR ;
KLEINMAN, HK ;
ROBEY, FA ;
YAMADA, Y .
CELL, 1987, 48 (06) :989-996
[8]  
Hynes RO, 1999, GUIDEBOOK EXTRACELLU, P422
[9]  
HYNES RO, 1990, FIBRONECTIONS
[10]  
JOHNSON WC, 1988, ARCH SURG-CHICAGO, V123, P434