Intrapartum assessment of fetal well-being: A comparison of scalp stimulation with scalp blood pH sampling

被引:38
作者
Elimian, A [1 ]
Figueroa, R [1 ]
Tejani, N [1 ]
机构
[1] NEW YORK MED COLL,DEPT OBSTET & GYNECOL,VALHALLA,NY
关键词
D O I
10.1016/S0029-7844(96)00525-X
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine whether the need for fetal scalp pH sampling is decreased by the scalp stimulation test and whether redefinition of reactivity and presence of variability further decrease the need for scalp pH sampling. Methods: One hundred eight women with fetal heart rate (FHR) patterns suggestive of acidosis underwent fetal scalp blood pH evaluations. Digital scalp stimulation was performed for 15 seconds 1-2 minutes before pH sampling. The study group was subdivided based on reactivity to scalp stimulation and scalp puncture and was correlated with pH values. Reactivity was defined as an acceleration of 15 beats per minute or more lasting at least 15 seconds and redefined as an acceleration of 10 beats per minute or more lasting at least 10 seconds. Nonreactive responses were subdivided based on FHR variability preceding the scalp stimulation and were correlated with pH values. Fisher exact test was used for analysis. Results: All 51 instances of acceleration of 15 beats per minute or more lasting at least 15 seconds following scalp stimulation had a scalp pH of 7.20 or more. Using an acceleration of 10 beats per minute or more lasting at least 10 seconds, seven more reactive responses were obtained after scalp stimulation, all with pH of 7.20 or more. The 15 instances in which the pH was less than 7.20 were nonreactive irrespective of the definition of reactivity (P < .001). Twenty-one of the 50 instances of nonreactive responses (reactive response: acceleration of 10 beats per minute or more lasting at least 10 seconds) had positive variability. Only two of these 21 (9.5%) instances compared to 13 of the 29 (45%) instances with negative variability had pH less than 7.20 (P < .007). Conclusions: The scalp stimulation test could decrease the need for fetal scalp blood sampling by 47%. Redefinition of reactivity could decrease the need for scalp sampling by 54%. In addition, assessment of FHR variability before scalp stimulation could decrease further the need for scalp blood sampling by 73%. Copyright (C) 1997 by The American College of Obstetricians and Gynecologists.
引用
收藏
页码:373 / 376
页数:4
相关论文
共 26 条
[1]  
American College of Obstetricians and Gynecologists, 1995, ACOG TECHN B, V207
[2]  
Beard R W, 1967, J Obstet Gynaecol Br Commonw, V74, P812
[3]  
BOENISCH A, 1976, J PERINAT MED, V4, P45
[4]   RELIABILITY OF FETAL BLOOD SAMPLING - MATERNAL-FETAL RELATIONSHIPS [J].
BOWE, ET ;
BEARD, RW ;
FINSTER, M ;
POPPERS, PJ ;
ADAMSONS, K ;
JAMES, LS .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1970, 107 (02) :279-&
[5]   THE SCALP STIMULATION TEST - A CLINICAL ALTERNATIVE TO FETAL SCALP BLOOD-SAMPLING [J].
CLARK, SL ;
GIMOVSKY, ML ;
MILLER, FC .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (03) :274-277
[6]   FETAL HEART-RATE RESPONSE TO SCALP BLOOD-SAMPLING [J].
CLARK, SL ;
GIMOVSKY, ML ;
MILLER, FC .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 144 (06) :706-708
[7]   INTRAPARTUM FETAL SURVEILLANCE - THE ROLE OF FETAL SCALP BLOOD-SAMPLING [J].
CLARK, SL ;
PAUL, RH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 153 (07) :717-720
[8]   ELECTRONIC FETAL HEART-RATE MONITORING DURING LABOR - DOES IT PREVENT PERINATAL ASPHYXIA AND CEREBRAL-PALSY [J].
COLDITZ, PB ;
HENDERSONSMART, DJ .
MEDICAL JOURNAL OF AUSTRALIA, 1990, 153 (02) :88-90
[9]   ANTEPARTUM FETAL HEART-RATE TESTING .6. PREDICTIVE RELIABILITY OF NORMAL TESTS IN THE PREVENTION OF ANTEPARTUM DEATH [J].
DRUZIN, ML ;
GRATACOS, J ;
PAUL, RH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 137 (06) :746-747
[10]   FETAL HEART-RATE RESPONSE TO VIBRATORY ACOUSTIC STIMULATION PREDICTS FETAL PH IN LABOR [J].
EDERSHEIM, TG ;
HUTSON, JM ;
DRUZIN, ML ;
KOGUT, EA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (06) :1557-1560