A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique

被引:103
作者
Engel, U
Bilgiç, AM
Haase, O
Voges, E
Broekaert, JAC
机构
[1] Univ Leipzig, Inst Analyt Chem, D-04103 Leipzig, Germany
[2] Univ Dortmund, Fac Elektrotech, D-44221 Dortmund, Germany
[3] Univ Dortmund, Fachbereich Chem, D-44221 Dortmund, Germany
关键词
D O I
10.1021/ac9906476
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new low-power, small-scale 2.45 GHz microwave plasma source at atmospheric pressure for atomic emission spectrometry based on microstrip technology is described. The MicroStrip Plasma (MSP) source was produced in microstrip technology on a fused-silica wafer and designed as an element-selective detector for miniaturized analytical applications. The electrodeless microwave-induced plasma (MIP) operates at microwave input power of 10-40 W and gas flows of 50-1000 mL.min(-1) of Ar. Rotational (OH) and excitation (Fe) temperatures were found to be 650 and 8000 K, respectively. Spatially resolved measurements of the Hg I 253.7-nm atomic emission line with an electronic slitless spectrograph (ESS) showed that a cylindrically symmetric plasma with a diameter of about 1 mm is obtained. With the MSP, Hg could be determined by applying the now injection cold vapor (FI-CV) technique with a detection limit of 50 pg.ml(-1). In terms of the relative standard deviation, a time stability of <1.4% for 45 replicates within 80 min can be realized at a concentration level of 10 ng.ml(-1) of Hg. Hg could be determined in the leachate of a certified standard reference soil (STSD-4) obtained by treatment with aqua regia at the 930 +/- 76 ng.g(-1) level. Results obtained by calibration with aqueous solutions of Hg and with standard addition were found to be in good agreement with those of cold-vapor atomic absorption spectrometry.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 21 条
[1]  
Ache HJ, 1996, FRESEN J ANAL CHEM, V355, P467
[2]   The effect of the reunification of Germany on the water chemistry and ecology of selected rivers [J].
Adams, MS ;
Kausch, H ;
Gaumert, T ;
Kruger, KE .
ENVIRONMENTAL CONSERVATION, 1996, 23 (01) :35-43
[3]  
BILGIC AM, IN PRESS PLASMA SOUR
[4]  
Craig, 1986, ORGANOMETALLIC COMPO
[5]   Miniaturisation: a well-defined trend in separation and preconcentration techniques [J].
deCastro, MDL ;
GamizGracia, L .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :23-40
[6]  
*DIN, 1997, 38414 DIN
[7]  
*DIN EN, 1997, 1483 DIN EN
[8]  
DOUBRAVA C, 1994, INT LAB, V24, P24
[9]   A molecular emission detector on a chip employing a direct current microplasma [J].
Eijkel, JCT ;
Stoeri, H ;
Manz, A .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2600-2606
[10]   Evaluation of the determination of mercury at the trace and ultra-trace levels in the presence of high concentrations of NaCl by flow injection cold vapour atomic absorption spectrometry using SnCl2 and NaBH4 as reductands [J].
Haase, O ;
Klare, M ;
Krengel-Rothensee, K ;
Broekaert, JAC .
ANALYST, 1998, 123 (06) :1219-1222