Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation - Long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up

被引:152
作者
Degertekin, M
Serruys, PW
Foley, DP
Tanabe, K
Regar, E
Vos, J
Smits, PC
van der Giessen, WJ
van den Brand, M
de Feyter, P
Popma, JJ
机构
[1] Erasmus Univ, Med Ctr, Ctr Thorax, Rotterdam, Netherlands
[2] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
stents; restenosis; ultrasonics; drugs;
D O I
10.1161/01.CIR.0000034447.02535.D5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. Methods and Results-Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 mug sirolimus/cm(2) metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. Conclusion-Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.
引用
收藏
页码:1610 / 1613
页数:4
相关论文
共 15 条
  • [1] Edge restenosis after implantation of high activity 32P radioactive β-emitting stents
    Albiero, R
    Nishida, T
    Adamian, M
    Amato, A
    Vaghetti, M
    Corvaja, N
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2000, 101 (21) : 2454 - 2457
  • [2] Late coronary occlusion after intracoronary brachytherapy
    Costa, MA
    Sabaté, M
    van der Giessen, WJ
    Kay, IP
    Cervinka, P
    Ligthart, JMR
    Serrano, P
    Coen, VLMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (08) : 789 - 792
  • [3] Ellis SG, 1999, CIRCULATION, V100, P799
  • [4] A novel approach to quantitative analysis of intra vascular ultrasound images
    Hamers, R
    Bruining, N
    Knook, M
    Sabate, M
    Roelandt, JRTC
    [J]. COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 589 - 592
  • [5] Kay IP, 2001, CIRCULATION, V103, P14
  • [6] Three-year follow-up after implantation of metallic coronary-artery stents
    Kimura, T
    Yokoi, H
    Nakagawa, Y
    Tamura, T
    Kaburagi, S
    Sawada, Y
    Sato, Y
    Yokoi, H
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) : 561 - 566
  • [7] Kozuma K, 1999, J INVASIVE CARDIOL, V11, P651
  • [8] A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.
    Morice, M
    Serruys, PW
    Sousa, JE
    Fajadet, J
    Hayashi, EB
    Perin, M
    Colombo, A
    Schuler, G
    Barragan, P
    Guagliumi, G
    Molnar, F
    Falotico, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) : 1773 - 1780
  • [9] Coronary restenosis elimination with a sirolimus eluting stent - First European human experience with 6-month angiographic and intravascular ultrasonic follow-up
    Rensing, BJ
    Vos, J
    Smits, PC
    Foley, DP
    van den Brand, MJBM
    van der Giessen, WJ
    de Feijter, PJ
    Serruys, PW
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (22) : 2125 - 2130
  • [10] Rapamycin eluting stent: the onset of a new era in interventional cardiology
    Serruys, PW
    Regar, E