Pseudo-electrokinetic packing of high efficiency columns for capillary electrochromatography

被引:23
作者
Stol, R
Mazereeuw, M
Tjaden, UR
van der Greef, J
机构
[1] Leiden Univ, Leiden Amsterdam Ctr Drug Res, Div Analyt Chem, NL-2300 RA Leiden, Netherlands
[2] Univ Amsterdam, Dept Analyt Chem, NL-1018 WV Amsterdam, Netherlands
[3] Unilever Res Labs Vlaardingen, NL-3133 AT Vlaardingen, Netherlands
关键词
capillary columns; stationary phases; electrochromatography; polynuclear aromatic hydrocarbons; clenbuterol; salbutamol; methadone;
D O I
10.1016/S0021-9673(99)01305-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved and easy electrokinetic packing procedure is presented for the production of stable capillary columns suitable for capillary electrochromatography (CEC). In pseudo-electrokinetic packing a high electric field is used in conjunction with a hydrodynamic flow. The packing of silica-based reversed-phase columns can be achieved with basic, commercially available capillary electrophoresis (CE) equipment in approximately 15 min. The procedure is robust and a high success rate is achieved. No steps which might damage the stationary phase are involved and only a minimum amount of packing material is required. Columns packed according to the developed procedure are operated at high electric field strengths during the CEC separation, without the application of a stabilising pressure. Columns are stable for at least hundred runs and were tested using mixtures of polycyclic aromatic hydrocarbons and positively charged drugs. Separations were performed in a relatively high conducting ammonium acetate buffer, with efficiencies of up to 283 000 plates/m. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 11 条
[1]  
BOUGHTFLOWER RJ, 1995, CHROMATOGRAPHIA, V41, P398
[2]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[3]   Automated capillary electrochromatography: Reliability and reproducibility studies [J].
Dulay, MT ;
Yan, C ;
Rakestraw, DJ ;
Zare, RN .
JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (02) :361-366
[4]   ELECTROCHROMATOGRAPHY IN PACKED TUBES USING 1.5 TO 50 MU-M SILICA-GELS AND ODS BONDED SILICA-GELS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1991, 32 (7-8) :317-328
[5]  
LEFIEVRE F, 1996, J CHROMATOGR A, V723, P145
[6]   ELECTROKINETIC FLOW IN A NARROW CYLINDRICAL CAPILLARY [J].
RICE, CL ;
WHITEHEAD, R .
JOURNAL OF PHYSICAL CHEMISTRY, 1965, 69 (11) :4017-+
[7]   Capillary electrochromatography using columns packed with a supercritical fluid carrier [J].
Robson, MM ;
Roulin, S ;
Shariff, SM ;
Raynor, MW ;
Bartle, KD ;
Clifford, AA ;
Meyers, P ;
Euerby, MR ;
Johnson, CM .
CHROMATOGRAPHIA, 1996, 43 (5-6) :313-321
[8]   Capillary electrochromatography with predetermined selectivity obtained through molecular imprinting [J].
Schweitz, L ;
Andersson, LI ;
Nilsson, S .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1179-1183
[9]   THE ANALYSIS OF PHARMACEUTICAL COMPOUNDS USING ELECTROCHROMATOGRAPHY [J].
SMITH, NW ;
EVANS, MB .
CHROMATOGRAPHIA, 1994, 38 (9-10) :649-657
[10]  
VERHEIJ ER, 1991, J CHROMATOGR, V554, P39