Poly(decyl methacrylate)-based fluorescent PEBBLE swarm nanosensors for measuring dissolved oxygen in biosamples

被引:70
作者
Cao, YF [1 ]
Koo, YEL [1 ]
Kopelman, R [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1039/b403086a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
150-250 nm Poly( decyl methacrylate) ( PDMA) fluorescent ratiometric nanosensors for dissolved oxygen have been developed. Platinum octaethylporphine ketone (PtOEPK), the oxygen-sensitive dye, and octaethylporphyrin (OEP), the oxygen-insensitive dye, have been incorporated into PDMA nanoparticles to make the sensors ratiometric. Based on the corresponding Stern-Volmer plot, these nanosensors exhibit almost complete linearity over the whole range of dissolved molecular oxygen from 0 to 42.5 ppm (deoxygenated to pure oxygen-bubbled water). The overall quenching response is up to 97.5%, the best so far for all dissolved oxygen optical sensors. These PEBBLE nanosensors also show very good reversibility and stability to leaching and photobleaching, as well as very short response times and no perturbation by proteins. In human plasma they demonstrate a robust oxygen sensing capability, little affected by light scattering and autofluorescence. Potential applications include intracellular oxygen imaging and microresolved pressure profiles in biological and other heterogenous environments.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 26 条
[1]  
Brasuel M, 2002, SENSOR MATER, V14, P309
[2]   Fluorescent nanosensors for intracellular chemical analysis: Decyl methacrylate liquid polymer matrix and ion exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells [J].
Brasuel, M ;
Kopelman, R ;
Miller, TJ ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2221-2228
[3]   PHOTOPHYSICS AND PHOTOCHEMISTRY OF OXYGEN SENSORS BASED ON LUMINESCENT TRANSITION-METAL COMPLEXES [J].
CARRAWAY, ER ;
DEMAS, JN ;
DEGRAFF, BA ;
BACON, JR .
ANALYTICAL CHEMISTRY, 1991, 63 (04) :337-342
[4]   MIGRATORY APTITUDES IN PINACOL REARRANGEMENT OF VIC-DIHYDROXYCHLORINS [J].
CHANG, CK ;
SOTIRIOU, C .
JOURNAL OF HETEROCYCLIC CHEMISTRY, 1985, 22 (06) :1739-1741
[5]   Subcellular optochemical nanobiosensors: probes encapsulated by biologically localised embedding (PEBBLEs) [J].
Clark, HA ;
Barker, SLR ;
Brasuel, M ;
Miller, MT ;
Monson, E ;
Parus, S ;
Shi, ZY ;
Song, A ;
Thorsrud, B ;
Kopelman, R ;
Ade, A ;
Meixner, W ;
Athey, B ;
Hoyer, M ;
Hill, D ;
Lightle, R ;
Philbert, MA .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :12-16
[6]  
DEMAS JN, 1991, ANAL CHEM, V63, P829
[7]   Response characteristics of thin film oxygen sensors, Pt and Pd octaethylporphyrins in polymer films [J].
Douglas, P ;
Eaton, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) :200-208
[8]  
Hitchman M.L., 1978, Measurement of dissolved oxygen. Chemical analysis
[9]   Syntheses of oxygen analogues of sulfhemes-A and -C [J].
Iakovides, P ;
Smith, KM .
TETRAHEDRON, 1996, 52 (04) :1123-1148
[10]   Real-time measurements of dissolved oxygen inside live cells by organically modified silicate fluorescent nanosensors [J].
Koo, YEL ;
Cao, YF ;
Kopelman, R ;
Koo, SM ;
Brasuel, M ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2498-2505