Profiling of polar metabolites in biological extracts using diamond hydride-based aqueous normal phase chromatography

被引:53
作者
Callahan, Damien L.
De Souza, David [1 ]
Bacic, Antony [1 ,2 ]
Roessner, Ute [2 ]
机构
[1] Univ Melbourne, Bio21 Mol Sci & Biotechnol Inst, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Australian Ctr Plant Funct Genom, Sch Bot, Melbourne, Vic 3010, Australia
关键词
Aqueous normal phase; ESI; Hydrophilic interaction chromatography; LC-MS; Metabolomics; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; INTERACTION LIQUID-CHROMATOGRAPHY; IONIZATION MASS-SPECTROMETRY; PRINCIPAL COMPONENT ANALYSIS; METABONOMIC ANALYSIS; STATIONARY-PHASE; RAT URINE; SEPARATION; MS; CLASSIFICATION;
D O I
10.1002/jssc.200900171
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly polar metabolites, such as sugars and Most amino acids arc not retained by conventional RP LC columns. Without Sufficient retention low concentration compounds are not detected due ion suppression and structural isomers are not resolved. In contrast, hydrophilic interaction chromatography (HILIC) and aqueous normal phase chromatography (ANP) retain compounds based on their hydrophilicity and therefore provides a means of separating highly polar compounds. Here, an ANP method based on the diamond hydride stationary phase is presented for profiling biological small molecules by LC. A rapid separation system based upon a fast gradient that delivers reproducible chromatography is presented. Approximately 1000 compounds were reproducibly detected in human urine samples and clear differences between these samples were identified. This chromatography was also applied to xylem fluid from soyabean (Glycine max) plants to which 400 compounds were detected. This method greatly increases the metabolite coverage over RP-only metabolite profiling in biological samples. We show that both forms of chromatography are necessary for untargeted comprehensive metabolite profiling and that the diamond hydride stationary phase provides a good option for polar metabolite analysis.
引用
收藏
页码:2273 / 2280
页数:8
相关论文
共 27 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   Hydrophilic interaction chromatography/electrospray mass spectrometry analysis of carbohydrate-related metabolites from Arabidopsis thaliana leaf tissue [J].
Antonio, Carla ;
Larson, Tony ;
Gilday, Alison ;
Graham, Ian ;
Bergstroem, Ed ;
Thomas-Oates, Jane .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (09) :1399-1407
[3]   Separation and quantitation of water soluble cellular metabolites by hydrophilic interaction chromatography-tandem mass spectrometry [J].
Bajad, Sunil U. ;
Lu, Wenyun ;
Kimball, Elizabeth H. ;
Yuan, Jie ;
Peterson, Celeste ;
Rabinowitz, Joshua D. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (01) :76-88
[4]   NMR-based metabonomic approaches for evaluating physiological influences on biofluid composition [J].
Bollard, ME ;
Stanley, EG ;
Lindon, JC ;
Nicholson, JK ;
Holmes, E .
NMR IN BIOMEDICINE, 2005, 18 (03) :143-162
[5]   Instrumental and experimental effects in LC-MS-based metabolomics [J].
Burton, Lyle ;
Ivosev, Gordana ;
Tate, Stephen ;
Impey, Gary ;
Wingate, Julie ;
Bonner, Ron .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :227-235
[6]   An optimized protocol for metabolome analysis in yeast using direct infusion electrospray mass spectrometry [J].
Castrillo, JI ;
Hayes, A ;
Mohammed, S ;
Gaskell, SJ ;
Oliver, SG .
PHYTOCHEMISTRY, 2003, 62 (06) :929-937
[7]   Hydrophilic interaction chromatography for mass spectrometric metabonomic studies of urine [J].
Cubbon, Simon ;
Bradbury, Timothy ;
Wilson, Julie ;
Thomas-Oates, Jane .
ANALYTICAL CHEMISTRY, 2007, 79 (23) :8911-8918
[8]   The Glycine max xylem sap and apoplast proteome [J].
Djordjevic, Michael A. ;
Oakes, Marie ;
Li, Dong Xue ;
Hwang, Cheol Ho ;
Hocart, Charles H. ;
Gresshoff, Peter M. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (09) :3771-3779
[9]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis [J].
Euerby, M ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 994 (1-2) :13-36
[10]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing polar embedded groups/amino endcappings using principal component analysis [J].
Euerby, MR ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) :1-15