Ten-year results of a cemented mild grit blasted titanium-aluminium-vanadium stem in total-hip-arthiroplasly.

被引:13
作者
Hinrichs, F [1 ]
Boudriot, U [1 ]
Griss, P [1 ]
机构
[1] Univ Marburg, Orthopad Klin, D-35033 Marburg, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2000年 / 138卷 / 01期
关键词
total-hip-arthroplasty; long-term-results; titanium-alloy; surface-roughness;
D O I
10.1055/s-2000-10113
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Are the results of cemented titanium hip arthroplasty as bad as described in literature? We present the 10-year results of a cemented mild grid blasted Titanium-Aluminium-Vanadium Stem in Total-Hip-Arthroplasty. Methods: The clinical and radiological reexamination was documented in standardized questionnaire in which several scores were integrated. All Xrays were stored and analysed by a special hardware and software computer system. Results: 35% of all patients could be reexamined both clinically and roentgenologically. 71 patients were male (mean age 56,1 years) and 130 female (mean age 59,3 years). The average follow-up period was 11 years and 4 months. The mean Merle d'Aubigne hip score increased from 10,5 to 16,0 points at the follow-up evaluation. Radiolucent lines were according to the zones of Gruen seen in 1% to 22% depending on the zone and the size of the femoral component. 18 reoperations of the femoral component (2,9%) had to be performed. The survivorship analysis (Kaplan-Meier) showed a 95,4% survival of the femoral component after 10 years. Conclusion: Our findings with a cemented mild grid blasted Titanium-Aluminum-vanadium stem demonstrate excelent results unlike it was reported for cemented femoral components of similar alloy but different design and cementation philosophy.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 23 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]
CALLAGHAN JJ, 1998, M HIP SOC ENGL
[4]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[5]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]
The control of new prosthetic implants [J].
Grigoris, P ;
Hamblen, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (06) :941-943
[7]
Griss P, 1982, Aktuelle Probl Chir Orthop, V21, P1
[8]
GRISS P, 1988, ORTHOP PRAX, V24, P766
[9]
GRISS P, 1991, HUFTENDOPROTHETIK, V2, P185
[10]
CLINICAL-RESULTS WITH A HYBRID TOTAL HIP-ARTHROPLASTY - A 3-6 YEAR FOLLOW-UP [J].
HELFEN, M ;
MALZER, U ;
PETERS, P ;
GRISS, P ;
HIMMELMANN, G ;
WEBER, E .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1993, 131 (06) :578-584