Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis

被引:198
作者
Kothari, M
Guermazi, A
von Ingersleben, G
Miaux, Y
Sieffert, M
Block, JE
Stevens, R
Peterfy, CG
机构
[1] Synarc Inc, Dept Reading Serv, San Francisco, CA 94105 USA
[2] Synarc Inc, Dept Sci Client Serv, San Francisco, CA 94105 USA
[3] Hoffmann La Roche Inc, Nutley, NJ 07110 USA
关键词
knee; osteoarthritis; radiography; joint space width;
D O I
10.1007/s00330-004-2312-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The validity of a non-fluoroscopic fixed-flexion radiographic acquisition and analysis protocol for measurement of joint space width (JSW) in knee osteoarthritis is determined. A cross-sectional study of 165 patients with documented knee osteoarthritis participating in a multicenter, prospective study of chondroprotective agents was performed. All patients had posteroanterior, weight-bearing, fixed-flexion radiography with 10degrees caudal beam angulation. A specially designed frame (SynaFlexer) was used to standardize the positioning. Minimum medial and lateral JSW were measured manually and twice by an automated analysis system to determine inter-technique and intra-reader concordance and reliability. A random subsample of 30 patients had repeat knee radiographs 2 weeks apart to estimate short-term reproducibility using automated analysis. Concordance between manual and automated medial JSW measurements was high (ICC=0.90); lateral compartment measurements showed somewhat less concordance (ICC=0.72). There was excellent concordance between repeated automated JSW measurements performed 6 months apart for the medial (ICC=0.94) and lateral (ICC=0.86) compartments. Short-term reproducibility for the subsample of 30 cases with repeat acquisitions demonstrated an average SD of 0.14 mm for medial JSW (CV=4.3%) and 0.23 mm for lateral JSW (CV=4.0%). Fixed-flexion radiography of the knee using a positioning device provides consistent, reliable and reproducible measurement of minimum JSW in knee osteoarthritis without the need for concurrent fluoroscopic guidance.
引用
收藏
页码:1568 / 1573
页数:6
相关论文
共 27 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]  
ALTMAN RD, 1995, OSTEOARTHR CARTILAGE, V3, P3
[3]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[4]  
BRANDT KD, 1991, ARTHRITIS RHEUM, V34, P1381
[5]  
Buckland-Wright JC, 1999, J RHEUMATOL, V26, P2664
[6]   ACCURACY AND PRECISION OF JOINT SPACE WIDTH MEASUREMENTS IN STANDARD AND MACRORADIOGRAPHS OF OSTEOARTHRITIC KNEES [J].
BUCKLANDWRIGHT, JC ;
MACFARLANE, DG ;
WILLIAMS, SA ;
WARD, RJ .
ANNALS OF THE RHEUMATIC DISEASES, 1995, 54 (11) :872-880
[7]   JOINT SPACE WIDTH MEASURES CARTILAGE THICKNESS IN OSTEOARTHRITIS OF THE KNEE - HIGH-RESOLUTION PLAIN FILM AND DOUBLE-CONTRAST MACRORADIOGRAPHIC INVESTIGATION [J].
BUCKLANDWRIGHT, JC ;
MACFARLANE, DG ;
LYNCH, JA ;
JASANI, MK ;
BRADSHAW, CR .
ANNALS OF THE RHEUMATIC DISEASES, 1995, 54 (04) :263-268
[8]  
DACRE JE, 1989, BRIT J RHEUMATOL, V28, P506
[9]   Trainable rule-based algorithm for the measurement of joint space width in digital radiographic images of the knee [J].
Duryea, J ;
Li, J ;
Peterfy, CG ;
Gordon, C ;
Genant, HK .
MEDICAL PHYSICS, 2000, 27 (03) :580-591
[10]   RELATIONSHIP BETWEEN ARTHROSCOPIC EVIDENCE OF CARTILAGE DAMAGE AND RADIOGRAPHIC EVIDENCE OF JOINT SPACE NARROWING IN EARLY OSTEOARTHRITIS OF THE KNEE [J].
FIFE, RS ;
BRANDT, KD ;
BRAUNSTEIN, EM ;
KATZ, BP ;
SHELBOURNE, KD ;
KALASINSKI, LA ;
RYAN, S .
ARTHRITIS AND RHEUMATISM, 1991, 34 (04) :377-382