Human femoral artery diameter in relation to knee extensor muscle mass, peak blood flow, and oxygen uptake

被引:68
作者
Rådegran, G [1 ]
Saltin, B [1 ]
机构
[1] Rigshosp, Copenhagen Muscle Res Ctr, Sect 7652, DK-2200 Copenhagen N, Denmark
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2000年 / 278卷 / 01期
关键词
exercise; hyperemia; ultrasound Doppler;
D O I
10.1152/ajpheart.2000.278.1.H162
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It is not known whether the diameter of peripheral conduit arteries may impose a limitation on muscle blood flow and oxygen uptake at peak effort in humans, and it is not clear whether these arteries are dimensioned in relation to the tissue volume they supply or, rather, to the type and intensity of muscular activity. In this study, eight humans, with a peak pulmonary oxygen uptake of 3.90 +/- 0.31 (range 2.29-5.03) l/min during ergometer cycle exercise, performed one-legged dynamic knee extensor exercise up to peak effort at 68 +/- 7 W (range 55-100 W). Peak values for knee extensor blood flow (thermodilution) and oxygen uptake of 6.06 +/- 0.74 (range 4.75-9.52) l/min and 874 +/- 124 (range 590-1,521) ml/min, respectively, were achieved. Pulmonary oxygen uptake reached a peak of 1.72 +/- 0.19 (range 1.54-2.33) l/min. Diameters of common and profunda femoral arteries determined by ultrasound Doppler were 10.6 +/- 0.4 (range 8.2-12.7) and 6.0 +/- 0.4 (range 4.5-8.0) mm, respectively. Thigh and quadriceps muscle volume measured by computer tomography were 10.06 +/- 0.66 (range 6.18-10.95) and 2.36 +/- 0.19 (range 1.31-3.27) liters, respectively. The common femoral artery diameter, but not that of the profunda branch, correlated with the thigh volume and quadriceps muscle mass. There were no relationships between either of the diameters and the absolute or muscle mass-related resting and peak values of blood flow and oxygen uptake, peak pulmonary oxygen uptake, or peak power output during knee extensor exercise. However, common femoral artery diameter correlated to peak pulmonary oxygen uptake during ergometer cycle exercise. In conclusion, common and profunda femoral artery diameters are sufficient to ensure delivery to the quadriceps muscle. However, the common branch may impose a limitation during ergometer cycle exercise.
引用
收藏
页码:H162 / H167
页数:6
相关论文
共 26 条
[1]   MAXIMAL PERFUSION OF SKELETAL-MUSCLE IN MAN [J].
ANDERSEN, P ;
SALTIN, B .
JOURNAL OF PHYSIOLOGY-LONDON, 1985, 366 (SEP) :233-249
[2]   DYNAMIC KNEE EXTENSION AS MODEL FOR STUDY OF ISOLATED EXERCISING MUSCLE IN HUMANS [J].
ANDERSEN, P ;
ADAMS, RP ;
SJOGAARD, G ;
THORBOE, A ;
SALTIN, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (05) :1647-1653
[3]   CARDIOVASCULAR ADAPTATIONS TO PHYSICAL-TRAINING [J].
BLOMQVIST, CG ;
SALTIN, B .
ANNUAL REVIEW OF PHYSIOLOGY, 1983, 45 :169-189
[4]   Maximum rate of oxygen uptake by human skeletal muscle in relation to maximal activities of enzymes in the Krebs cycle [J].
Blomstrand, E ;
Radegran, G ;
Saltin, B .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 501 (02) :455-460
[5]  
CHAPMAN JV, 1990, NONINVASIVE EVALUATI, P1
[6]   ENZYME-ACTIVITY AND FIBER COMPOSITION IN SKELETAL-MUSCLE OF UNTRAINED AND TRAINED MEN [J].
GOLLNICK, PD ;
SALTIN, B ;
SAUBERT, CW ;
ARMSTRONG, RB ;
PIEHL, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 33 (03) :312-+
[7]   Structural and functional adaptations of the cardiovascular system by training [J].
Huonker, M ;
Halle, M ;
Keul, J .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1996, 17 :S164-S172
[8]  
HUONKER M, 1994, EUROP J PHYSL, V69, P40
[9]  
Keul J, 1996, RES Q EXERCISE SPORT, V67, pS29
[10]   CONDUCTED VASODILATION ELEVATES FLOW IN ARTERIOLE NETWORKS OF HAMSTER STRIATED-MUSCLE [J].
KURJIAKA, DT ;
SEGAL, SS .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (05) :H1723-H1728