Clinical evaluation of diminished early expiratory flow (DEEF) ventilation in mechanically ventilated COPD patients

被引:1
作者
Gultuna, I
Huygen, PEM
Ince, C
Strijdhorst, H
Bogaard, JM
Bruining, HA
机构
[1] UNIV ROTTERDAM HOSP,DEPT SURG,INTENS CARE UNIT,3015 GD ROTTERDAM,NETHERLANDS
[2] UNIV ROTTERDAM HOSP,DEPT PULM DIS,3015 GD ROTTERDAM,NETHERLANDS
关键词
diminished early expiratory flow; end-expiratory lung volume; COPD; wash-out test; pursed lips breathing; ventilation inhomogeneity;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the cardiopulmonary effects, especially the end-expiratory lung volume (EEV) and ventilation inhomogeneity during diminished early expiratory flow ventilation (DEEF), which resembles pursed-lips breathing, with the conventional intermittent positive pressure ventilation (IPPV) in postoperative mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). Design: A prospective study measuring cardiopulmonary parameters during IPPV, DEEP, and positive end-expiratory pressure (PEEP) as a control mode. In the PEEP mode, PEEP values were chosen such that the mean airway pressure during a breath cycle was equal to that during the DEEF mode, which was higher than the conventional IPPV mode. Setting: Surgical intensive care unit of a university hospital. Patients: 20 postoperative mechanically ventilated COPD patients who were optimally pretreated and had normal blood oxygenation. Interventions: Measurements were started in the IPPV (IPPV1) mode, continued in a randomized order with DEEF or PEEP, and completed with a second IPPV (IPPV2) mode, with Ih equilibration time in each mode before each measurement. Measurements and results. A multi-breath indicator gas wash-out test was used to calculate the EEV and ventilation inhomogeneity. There was a 9% increase (p < 0.05) in the mean EEV during both the DEEF and PEEP mode compared to IPPV. No significant changes in the ventilation inhomogeneity and deadspace fractions or the hemodynamic parameters were found during the different ventilatory modes. Conclusions: There was no improvement in pulmonary and hemodynamic parameters during the DEEP mode in comparison to the IPPV mode. The small increase in EEV during DEEP was probably caused by the slightly higher mean expiratory pressures as in the PEEP mode. However, this had no effect on the hemodynamic parameters. As we could not observe any improvement with the DEEP ventilation in our optimally pretreated postoperative COPD patients, we do not advise applying this therapy in this group of patients, since this mode of ventilation may cause barotrauma if not monitored adequately.
引用
收藏
页码:539 / 545
页数:7
相关论文
共 23 条
[1]  
BARACH AL, 1973, B NEW YORK ACAD MED, V49, P666
[2]   Effect of breathing gases under positive pressure on lumens of small and medium-sized bronchi [J].
Barach, AL ;
Swenson, P .
ARCHIVES OF INTERNAL MEDICINE, 1939, 63 (05) :946-948
[3]   Physiological methods in the diagnosis and treatment of asthma and emphysema [J].
Barach, AL .
ANNALS OF INTERNAL MEDICINE, 1938, 12 (04) :454-481
[4]   VENTILATION WITH END-EXPIRATORY PRESSURE IN ACUTE LUNG-DISEASE [J].
FALKE, KJ ;
LAVER, MB ;
KUMAR, A ;
PONTOPPI.H ;
LEITH, DE ;
GEFFIN, B .
JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (09) :2315-+
[5]   TREATMENT OF IDIOPATHIC RESPIRATORY-DISTRESS SYNDROME WITH CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
GREGORY, GA ;
KITTERMAN, JA ;
PHIBBS, RH ;
TOOLEY, WH ;
HAMILTON, WK .
NEW ENGLAND JOURNAL OF MEDICINE, 1971, 284 (24) :1333-+
[6]   RESPIRATORY SYSTEM MECHANICS IN VENTILATED PATIENTS - TECHNIQUES AND INDICATIONS [J].
HUBMAYR, RD ;
GAY, PC ;
TAYYAB, M .
MAYO CLINIC PROCEEDINGS, 1987, 62 (05) :358-368
[7]   A NEW VENTILATION INHOMOGENEITY INDEX FROM MULTIPLE BREATH INDICATOR GAS WASHOUT TESTS IN MECHANICALLY VENTILATED PATIENTS [J].
HUYGEN, PE ;
GULTUNA, I ;
INCE, C ;
ZWART, A ;
BOGAARD, JM ;
FEENSTRA, BW ;
BRUINING, HA .
CRITICAL CARE MEDICINE, 1993, 21 (08) :1149-1158
[8]   PDPS - A PULMONARY DATA-PROCESSING SYSTEM FOR ASSESSMENT OF GAS-EXCHANGE PROPERTIES BY MULTIPLE GAS WASH-OUT [J].
HUYGEN, PEM ;
FEENSTRA, BWA ;
HOORN, E ;
JANSEN, JRC ;
ZWART, A .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1991, 36 (04) :223-235
[9]  
HUYGEN PEM, 1990, CRIT CARE MED, V18, P754
[10]  
INGRAM RH, 1967, AM REV RESPIR DIS, V96, P381