Milrinone Increases Flow in Coronary Artery Bypass Grafts After Cardiopulmonary Bypass: A Prospective, Randomized, Double-Blind, Placebo-Controlled Study

被引:11
作者
Arbeus, Mikael [1 ]
Axelsson, Birger [1 ]
Friberg, Orjan [1 ]
Magnuson, Anders [2 ]
Bodin, Lennart [2 ]
Hultman, Jan [3 ]
机构
[1] Orebro Univ Hosp, Dept Cardiothorac Surg & Anesthesiol, SE-70185 Orebro, Sweden
[2] Orebro Univ Hosp, Stat & Epidemiol Unit, SE-70185 Orebro, Sweden
[3] Univ Uppsala Hosp, Dept Thorac & Cardiovasc Anesthesia, Uppsala, Sweden
关键词
myocardial revascularization; CABG; coronary graft flow; chemicals and drugs; phosphodiesterase inhibitor; milrinone; transesophageal echocardiography; INTERNAL MAMMARY ARTERY; SAPHENOUS-VEIN GRAFTS; CONGESTIVE-HEART-FAILURE; CARDIAC-SURGERY; MYOCARDIAL ENERGETICS; INTRAVENOUS MILRINONE; SURROUNDING TISSUE; EJECTION FRACTION; BLOOD-FLOW; DOBUTAMINE;
D O I
10.1053/j.jvca.2008.07.005
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Objective: To compare the effects of a bolus of milrinone, 50 mu g/kg, versus placebo on flow in coronary artery bypass grafts after cardiopulmonary bypass (CPB). Design: A prospective, randomized, double-blind study. Setting: A university hospital. Participants: Forty-four patients with stable angina and left ventricular ejection fraction > 30% scheduled for elective coronary artery bypass graft (CABG) surgery were included. Intervention: Patients were randomized to receive 50 mu g/kg of milrinone (n = 22) or placebo (n = 22) after aortic declamping. Measurements and Main Results: The flow in coronary artery bypass grafts was measured with a transit time flow meter at 10 minutes and 30 minutes after termination of CPB. The hemodynamic evaluation included transesophageal echocardiography, mean arterial pressure (MAP), heart rate, and intracavitary measurement of left ventricular end-diastolic pressure (LVEDP). The flow in the saphenous vein grafts was significantly higher in the milrinone group when compared with the placebo group both at 10 and 30 minutes after termination of CPB (p < 0.001). At 10 minutes, the flow was 64.5 +/- 37.4 mL/min (mean +/- standard deviation) and 43.6 +/- 25.7 mL/min in nonsequential vein grafts for milrinone and placebo, respectively. Corresponding values at 30 minutes were 54.8 +/- 29.9 mL/min and 35.3 +/- 22.4 mL/min. The left internal thoracic artery (LITA) flow was higher in the milrinone group but did not reach statistical significance. The fractional area change was higher, and the MAP and calculated pressure gradient (MAP-LVEDP) were lower at 10 minutes in the milrinone group. Conclusion: Milrinone significantly increases the flow in anastomosed saphenous vein grafts after CPB, and has beneficial effects on left ventricular function. (c) 2009 Elsevier Inc. All rights reserved
引用
收藏
页码:48 / 53
页数:6
相关论文
共 31 条
[1]
PHARMACOKINETICS OF INTRAVENOUS MILRINONE IN PATIENTS UNDERGOING CARDIAC-SURGERY [J].
BAILEY, JM ;
LEVY, JH ;
KIKURA, M ;
SZLAM, F ;
HUG, CC .
ANESTHESIOLOGY, 1994, 81 (03) :616-622
[2]
A PHARMACOKINETIC AND PHARMACODYNAMIC EVALUATION OF MILRINONE IN ADULTS UNDERGOING CARDIAC-SURGERY [J].
BUTTERWORTH, JF ;
HINES, RL ;
ROYSTER, RL ;
JAMES, RL .
ANESTHESIA AND ANALGESIA, 1995, 81 (04) :783-792
[3]
ESTIMATION OF LEFT-VENTRICULAR VOLUME AND EJECTION FRACTION BY 2-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY - COMPARISON OF SHORT AXIS IMAGING AND SIMULTANEOUS RADIONUCLIDE ANGIOGRAPHY [J].
CLEMENTS, FM ;
HARPOLE, DH ;
QUILL, T ;
JONES, RH ;
MCCANN, RL .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 64 (03) :331-336
[4]
DINARDO JA, 1991, J THORAC CARDIOV SUR, V102, P730
[5]
A placebo-controlled trial verifying the efficacy of milrinone in weaning high-risk patients from cardiopulmonary bypass [J].
Doolan, LA ;
Jones, EF ;
Kalman, J ;
Burton, BF ;
Tonkin, AM .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (01) :37-41
[6]
Feneck R O, 1992, J Cardiothorac Vasc Anesth, V6, P554, DOI 10.1016/1053-0770(92)90097-Q
[7]
Feneck R O, 1992, J Cardiothorac Vasc Anesth, V6, P563, DOI 10.1016/1053-0770(92)90098-R
[8]
Comparison of the hemodynamic effects of milrinone with dobutamine in patients after cardiac surgery [J].
Feneck, RO ;
Sherry, KM ;
Withington, S ;
Oduro-Dominah, A .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (03) :306-315
[9]
Improved performance with single dose phosphodiesterase inhibitor? [J].
Fogg, KJ ;
Royston, D .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (05) :663-666
[10]
COMPARISON OF LEFT-VENTRICULAR FUNCTION BY ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION AND BY RADIONUCLIDE EJECTION FRACTION [J].
GORCSAN, J ;
LAZAR, JM ;
SCHULMAN, DS ;
FOLLANSBEE, WP .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (11) :810-815