Determination of eugenol diffusion through LLDPE using FTIR-ATR flow cell and HPLC techniques

被引:70
作者
Dhoot, G. [1 ]
Auras, R. [1 ]
Rubino, M. [1 ]
Dolan, K.
Soto-Valdez, H. [2 ]
机构
[1] Michigan State Univ, Sch Packaging, E Lansing, MI 48824 USA
[2] AC, Ctr Invest Alimentac & Desarrollo, Hermosillo 83000, Sonora, Mexico
关键词
Eugenol; LLDPE; FTIR-ATR; THIN-FILMS; SOLUTE DIFFUSION; IR SPECTROSCOPY; WATER DIFFUSION; ESSENTIAL OILS; IN-SITU; POLYMER; TRANSPORT; POLYETHYLENE; COEFFICIENT;
D O I
10.1016/j.polymer.2009.01.026
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A time-resolved Fourier Transform Infrared-Attenuated Total Reflectance Spectroscopy (FTIR-ATR) technique was set up and used to study the diffusion of eugenol through Linear Low Density Polyethylene (LLDPE) at 16, 23 and 40 degrees C. The 1514 cm(-1) peak for eugenol (aromatic -C=C- stretching) was monitored over time and used to determine the diffusion coefficient (D). The Fickian model was found to fit well to the experimental data and the D value of eugenol through LLDPE was found to be between 1.05 +/- 0.01 and 13.23 +/- 0.18 x 10(-10) cm(2)/s. The FTIR-ATR results were compared with one and two side diffusion process using a permeation cell and quantified by High Performance Liquid Chromatography (HPLC) technique. Eugenol sorbed in LLDPE samples at different times, was extracted in methanol and the concentration determined by HPLC. The diffusion coefficient by both two-sided and one-sided HPLC technique was found to be approximately three times higher than the FTIR-ATR values although they were in the same order of magnitude of 10(-10) cm(2)/s. The difference between the FTIR-ATR and HPLC results was mainly attributed to difference between the two measuring techniques. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1470 / 1482
页数:13
相关论文
共 48 条
[1]  
ASFOUR AA, 2003, J APPL POLYM SCI, V38, P1503
[2]   An attenuated total reflectance cell for analysis of small molecule diffusion in polymer thin films with Fourier-transform infrared spectroscopy [J].
Balik, CM ;
Simendinger, WH .
POLYMER, 1998, 39 (20) :4723-4728
[3]  
Beck J.V., 1977, Parameter estimation in engineering and science
[4]   Regions of interest in FTIR imaging applications: Diffusion of nicotine into ethylene-co-vinyl acetate films [J].
Bobiak, JP ;
Koenig, JL .
JOURNAL OF CONTROLLED RELEASE, 2005, 106 (03) :329-338
[5]   Testing limonene diffusion through food contact polyethylene by FT-IR spectroscopy: Film thickness, permeant concentration and outer medium effects [J].
Cava, D ;
Catala, R ;
Gavara, R ;
Lagaron, JM .
POLYMER TESTING, 2005, 24 (04) :483-489
[6]   On the applicability of FT-IR spectroscopy to test aroma transport properties in polymer films [J].
Cava, D ;
Lagarón, JM ;
López-Rubio, A ;
Catalá, R ;
Gavara, R .
POLYMER TESTING, 2004, 23 (05) :551-557
[7]  
Crank J., 1979, The mathematics of diffusion
[8]  
DOOPERS LM, 2006, YARWOOD J POLYM, V47, P2714
[9]   Time-resolved Fourier transform infrared/attenuated total reflection spectroscopy for the measurement of molecular diffusion in polymers [J].
Elabd, YA ;
Baschetti, MG ;
Barbari, TA .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2003, 41 (22) :2794-2807
[10]  
ESMAIEL J, 1993, MACROMOLECULES, V26, P2175