Microchip capillary electrophoresis coupled with an end-column electrochemiluminescence detection

被引:25
作者
Ding, Shou-Nian [1 ]
Xu, Jing-Juan [1 ]
Chen, Hong-Yuan [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
基金
中国国家自然科学基金;
关键词
microchip electrophoresis; electrochemiluminescence; tris(2,2 '-bipyridyl)ruthenium(II);
D O I
10.1016/j.talanta.2006.02.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An easy and universal wall-jet configuration for microchip CE-ECL detection system was constructed and investigated in this work. Two detection modes of pre-column and post-column were applied to the above system. TPA, tramadol and lidocaine were chosen as model analytes to estimate the system in both modes. The important operational parameters such as the concentration of luminescent reagent and the distance between the separation outlet and the working electrode were optimally obtained and compared for the first time. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:403 / 407
页数:5
相关论文
共 37 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[3]   Chemiluminescent detection of amines and amino acids using in situ generated Ru(bpy)33+ following separation by capillary electrophoresis [J].
Bobbitt, DR ;
Jackson, WA ;
Hendrickson, HP .
TALANTA, 1998, 46 (04) :565-572
[4]   ROLE OF ELECTRON-DONATING WITHDRAWING CHARACTER, PH, AND STOICHIOMETRY ON THE CHEMILUMINESCENT REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS [J].
BRUNE, SN ;
BOBBITT, DR .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :166-170
[5]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3683, DOI 10.1002/1522-2683(200211)23:21<3683::AID-ELPS3683>3.0.CO
[6]  
2-F
[7]  
Cao WD, 2002, ELECTROANAL, V14, P1571, DOI 10.1002/1521-4109(200211)14:22<1571::AID-ELAN1571>3.0.CO
[8]  
2-X
[9]   Tris(2,2′-bipyridyl)ruthenium(III)-based electrochemiluminescence detector with indium/tin oxide working electrode for capillary electrophoresis [J].
Chiang, MT ;
Whang, CW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 934 (1-2) :59-66
[10]   A simple and low-cost electrochemiluminescence detector for capillary electrophoresis [J].
Chiang, MT ;
Lu, MC ;
Whang, CW .
ELECTROPHORESIS, 2003, 24 (17) :3033-3039