Discrete scintillator coupled mercuric iodide photodetector arrays for breast imaging

被引:16
作者
Tornai, MP [1 ]
Patt, BE [1 ]
Iwanczyk, JS [1 ]
Levin, CS [1 ]
Hoffman, EJ [1 ]
机构
[1] ADV DETECTORS INC,CAMARILLO,CA 93012
关键词
D O I
10.1109/23.596976
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multi-element (4x4) imaging arrays with high resolution collimators, size matched to discrete CsI(Tl) scintillator arrays and mercuric iodide photodetector arrays (HgI2 PDA) were developed as prototypes for larger 16x16 element arrays for breast imaging. The compact nature of the arrays allows detector positioning in close proximity to the breast to eliminate activity not in the line-of-sight of the collimator, thus reducing image background. Short collimators, size matched to less than or equal to 1.5x1.5 mm(2) scintillators show a factor of 2 and 3.4 improvement in spatial resolution and efficiency, respectively, compared to high resolution collimated gamma cameras for the anticipated compressed breast geometries. Monte Carlo simulations, confirmed by measurements, demonstrated that scintillator length played a greater role in efficiency and photofraction for 140 keV gammas than cross sectional area, which affects intrinsic spatial resolution. Simulations also demonstrated that an increase in the ratio of scintillator area to length corresponds to an improvement in light collection. Electronic noise was below 40 e(-) RMS indicating that detector resolution was not noise limited. The high quantum efficiency and spectral match of prototype unity gain HgI2 PDAs coupled to 1x1x2.5 mm(3) and 2x2x4 mm(3) CsI(Tl) scintillators demonstrated energy resolutions of 9.4% and 8.8% FWHM at 140 keV, respectively, without the spectral tailing observed in standard high-Z, compound semiconductor detectors. Line spread function measurements matched the scintillator size and pitch, and small, complex phantoms were easily imaged.
引用
收藏
页码:1127 / 1133
页数:7
相关论文
共 23 条
[1]   CLINICAL-EXPERIENCE WITH TC-99M MIBI IMAGING IN PATIENTS WITH MALIGNANT-TUMORS - PRELIMINARY-RESULTS AND COMPARISON WITH TL-201 [J].
AKTOLUN, C ;
BAYHAN, H ;
KIR, M .
CLINICAL NUCLEAR MEDICINE, 1992, 17 (03) :171-176
[2]   SENSITIVITY AND SPECIFICITY OF 1ST SCREEN MAMMOGRAPHY IN THE CANADIAN NATIONAL BREAST SCREENING STUDY - A PRELIMINARY-REPORT FROM 5 CENTERS [J].
BAINES, CJ ;
MILLER, AB ;
WALL, C ;
MCFARLANE, DV ;
SIMOR, IS ;
JONG, R ;
SHAPIRO, BJ ;
AUDET, L ;
PETITCLERC, M ;
OUIMETOLIVA, D ;
LADOUCEUR, J ;
HEBERT, G ;
MINUK, T ;
HARDY, G ;
STANDING, HK .
RADIOLOGY, 1986, 160 (02) :295-298
[3]   THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS [J].
BIRD, AJ ;
CARTER, T ;
DEAN, AJ ;
RAMSDEN, D ;
SWINYARD, BM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :395-399
[4]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[5]  
IWANCZYK JS, 1995, SEMICONDUCTORS ROOM, V43, P615
[6]   TC-99M MIBI UPTAKE IN BREAST-CARCINOMA AND AXILLARY LYMPH-NODE METASTASES [J].
KAO, CH ;
WANG, SJ ;
YEH, SH .
CLINICAL NUCLEAR MEDICINE, 1994, 19 (10) :898-900
[7]  
KHALKHALI I, 1995, J NUCL MED, V36, P1784
[8]   SCINTIMAMMOGRAPHY - THE COMPLEMENTARY ROLE OF TC-99M SESTAMIBI PRONE BREAST IMAGING FOR THE DIAGNOSIS OF BREAST-CARCINOMA [J].
KHALKHALI, I ;
CUTRONE, JA ;
MENA, IG ;
DIGGLES, LE ;
VENEGAS, RJ ;
VARGAS, HI ;
JACKSON, BL ;
KHALKHALI, S ;
MOSS, JF ;
KLEIN, SR .
RADIOLOGY, 1995, 196 (02) :421-426
[9]   REVIEW OF IMAGING TECHNIQUES FOR THE DIAGNOSIS OF BREAST-CANCER - A NEW ROLE OF PRONE SCINTIMAMMOGRAPHY USING TC-99M SESTAMIBI [J].
KHALKHALI, I ;
MENA, I ;
DIGGLES, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (04) :357-362
[10]   LIGHT COLLECTION IN SCINTILLATION DETECTOR COMPOSITES FOR NEUTRON DETECTION [J].
KNOLL, GF ;
KNOLL, TF ;
HENDERSON, TM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :872-875