Penile prosthesis cultures during revision surgery: A multicenter study

被引:97
作者
Henry, GD
Wilson, SK
Delk, JR
Carson, CC
Silverstein, A
Cleves, MA
Donatucci, CF
机构
[1] Inst Urol Excellence, Van Buren, AR USA
[2] Univ Arkansas Med Sci, Dept Biostat, Little Rock, AR 72205 USA
[3] Univ N Carolina, Dept Urol, Chapel Hill, NC USA
[4] Duke Univ, Dept Surg, Div Urol, Durham, NC USA
关键词
infection; prostheses and implants; impotence; bacteria;
D O I
10.1097/01.ju.0000132141.48587.f1
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Initial implantation of inflatable penile prosthesis has a 3% risk of infection. Reoperation of penile implants has a higher rate of infection, estimated between 10% and 18%. To explain the higher risk in revision surgery in this prospective study we cultured clinically uninfected prostheses requiring revision. Prosthesis pain was also investigated as a predictor of positive culture. Materials and Methods: At 3 institutions cultures were prospectively obtained from 77 clinically uninfected penile prostheses at revision surgery. Immediately upon surgical exposure of the pump cultures were obtained. If a bacterial biofilm was noted on any component it was additionally cultured. All culture isolates positive for a staphylococcus species were tested for sensitivity to rifampin and tetracycline (minocycline). An implant is now available that is coated with these antibiotics. Patient history of chronic prosthesis pain was ascertained. Results: Culture positive bacteria were found in 54 of 77 (70%) patients with clinically uninfected penile prostheses. In some patients more than 1 organism grew and, occasionally, the pump culture was negative but the biofilm was positive. Of 54 patients 49 had positive (90%) culture for staphylococcus genus with 10 different species. All staphylococcal species were sensitive to rifampin and/or tetracycline. We did not find a significant association between prosthesis related pain and culture laboratory results. Conclusions: The majority of clinically uninfected penile prostheses have organisms growing in the implant spaces at reoperation. Most of these organisms are staphylococcal species that are sensitive to rifampin/minocycline.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 20 条
[1]  
Blum M D, 1989, Infect Dis Clin North Am, V3, P259
[2]   The prosthesis salvage operation: Immediate replacement of the infected penile prosthesis [J].
Brant, MD ;
Ludlow, JK ;
Mulcahy, JJ .
JOURNAL OF UROLOGY, 1996, 155 (01) :155-157
[3]   Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants [J].
Carson, CC .
JOURNAL OF UROLOGY, 2004, 171 (04) :1611-1614
[4]   LATE HEMATOGENOUS INFECTION OF PENILE PROSTHESES [J].
CARSON, CC ;
ROBERTSON, CN .
JOURNAL OF UROLOGY, 1988, 139 (01) :50-52
[5]   The nose: an underestimated source of Staphylococcus aureus causing wound infection [J].
Casewell, MW .
JOURNAL OF HOSPITAL INFECTION, 1998, 40 :S3-S11
[6]  
Cleves M.A., 2002, INTRO SURVIVAL ANAL
[7]   Risk factors for penile prosthetic infection [J].
Jarow, JP .
JOURNAL OF UROLOGY, 1996, 156 (02) :402-404
[8]  
Klein JP., 1997, SURVIVAL ANAL TECHNI, V149, P95
[9]  
Lee E. T., 1992, Statistical Methods for Survival Data Analysis, V2nd
[10]   Antibacterial activity of antibiotic coated silicone grafts [J].
Li, HK ;
Fairfax, MR ;
Dubocq, F ;
Darouiche, RO ;
Rajpurkar, A ;
Thompson, M ;
Tefilli, MV ;
Dhabuwala, CB .
JOURNAL OF UROLOGY, 1998, 160 (05) :1910-1913