New Methods in Diffusion-Weighted and Diffusion Tensor Imaging

被引:52
作者
Bammer, Roland [1 ]
Holdsworth, Samantha J. [1 ]
Veldhuis, Wouter B. [2 ]
Skare, Stefan T. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas Ctr, Stanford, CA 94305 USA
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
基金
美国国家卫生研究院;
关键词
Diffusion-weighted MR imaging; Diffusion-weighted imaging; Diffusion tensor imaging; Parallel imaging; Diffusion-weighted whole-body imaging with background body signal suppression; Whole-body diffusion imaging; STATE FREE PRECESSION; ECHO-PLANAR IMAGES; SINGLE-SHOT; SPIN-ECHO; PROPELLER MRI; IN-VIVO; GEOMETRIC DISTORTIONS; CEREBRAL-ISCHEMIA; MOTION ARTIFACTS; PHASE CORRECTION;
D O I
10.1016/j.mric.2009.01.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Considerable strides have been made by countless individual researchers in diffusion-weighted imaging (DWI) to push DWI from an experimental tool, limited to a few institutions with specialized instrumentation, to a powerful tool used routinely for diagnostic imaging. The field of DWI constantly evolves, and progress has been made on several fronts. These developments are primarily composed of improved robustness against patient and physiologic motion, increased spatial resolution, new biophysical and tissue models, and new clinical applications for DWI. This article aims to provide a succinct overview of some of these new developments and a description of some of the major challenges associated with DWI.
引用
收藏
页码:175 / +
页数:31
相关论文
共 119 条
[1]
AKSOY M, 2008, 16 ANN M ISMRM TOR C
[2]
Albers GW, 1999, NEUROLOGY, V52, pA453
[3]
Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :527-533
[4]
ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[5]
A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI [J].
Andersson, JLR ;
Skare, S .
NEUROIMAGE, 2002, 16 (01) :177-199
[6]
How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[7]
White matter tractography by means of turboprop diffusion tensor imaging [J].
Arfanakis, K ;
Gui, MZ ;
Lazar, M .
WHITE MATTER IN COGNITIVE NEUROSCIENCE: ADVANCES IN DIFFUSION TENSOR IMAGING AND ITS APPLICATIONS, 2005, 1064 :78-+
[8]
k-space undersampling in PROPELLER imaging [J].
Arfanakis, K ;
Tamhane, AA ;
Pipe, JG ;
Anastasio, MA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :675-683
[9]
Assaf Y, 1999, NMR BIOMED, V12, P335, DOI 10.1002/(SICI)1099-1492(199910)12:6<335::AID-NBM581>3.0.CO
[10]
2-A