Determination of MAG-camptothecin, a new polymer-bound Camptothecin derivative, and free Camptothecin in dog plasma by HPLC with fluorimetric detection

被引:19
作者
Fraier, D [1 ]
Frigerio, E [1 ]
Brianceschi, G [1 ]
Casati, M [1 ]
Benecchi, A [1 ]
James, C [1 ]
机构
[1] Pharmacia & Upjohn Inc, Drug Metab Res, Pharmacokinet & Metab Dept, I-20014 Milan, Italy
关键词
polymer-bound Camptothecin derivative; Camptothecin; HPLC determination; fluorimetric detection; dog plasma;
D O I
10.1016/S0731-7085(99)00315-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high throughput, selective and sensitive high-performance liquid chromatographic (HPLC) method for the determination of a water-soluble polymer-bound Camptothecin conjugate (MAG-CPT) and Camptothecin (CPT) in dog plasma has been developed and validated. The method involved the analysis of free and total CPT (free + polymer-bound). Free CPT (intact lactone plus carboxylate) was extracted from acidified plasma using Oasis(TM) SPE material in 96-well plates. For the assay of the total CPT, plasma proteins were first precipitated with methanol in a 96-well prate containing a 10-mu m melt blown polypropylene membrane. The methanolic supernatant was separated and collected into a second 96-well plate by simply applying vacuum to the plate. After hydrolysis at pH 9.8 for 18 h and re-acidification, samples were injected directly from the collection plate onto the HPLC system. MAG-CPT concentration was then calculated by subtraction of free from total CPT. The LLOQs of the method were 1.17 ng/ml for foe CPT and 103.10 ng/ml (as CPT equivalent) for MAG-CPT using 0.1 and 0.05 ml of plasma, respectively. Linearity, precision, accuracy and recovery of the method were evaluated. The stability of MAG-CPT in plasma alone and after its stabilisation was carefully evaluated. No interference from blank dog, mouse and human plasma was observed. The suitability of the method for in vivo samples was assessed by the analysis of samples obtained from dogs that had received a single and 5-day repeated dose of MAG-CPT. 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:505 / 514
页数:10
相关论文
共 15 条
[1]   High-performance liquid chromatographic quantitation of total and lactone 20(S)camptothecin in patients receiving oral 20(S)camptothecin [J].
Ahmed, F ;
Vyas, V ;
Saleem, A ;
Li, XG ;
Zamek, R ;
Cornfield, A ;
Haluska, P ;
Ibrahim, N ;
Rubin, EH ;
Gupta, E .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :227-233
[2]  
Conover CD, 1997, ANTICANCER RES, V17, P3361
[3]   Camptothecin delivery systems: enhanced efficacy and tumor accumulation of camptothecin following its conjugation to polyethylene glycol via a glycine linker [J].
Conover, CD ;
Greenwald, RB ;
Pendri, A ;
Gilbert, CW ;
Shum, KL .
CANCER CHEMOTHERAPY AND PHARMACOLOGY, 1998, 42 (05) :407-414
[4]   DRUG POLYMER CONJUGATES - POTENTIAL FOR IMPROVED CHEMOTHERAPY [J].
DUNCAN, R .
ANTI-CANCER DRUGS, 1992, 3 (03) :175-210
[5]   A KINETIC AND MECHANISTIC STUDY OF THE HYDROLYSIS OF CAMPTOTHECIN AND SOME ANALOGS [J].
FASSBERG, J ;
STELLA, VJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1992, 81 (07) :676-684
[6]   Determination of a new polymer-bound paclitaxel derivative (PNU 166945), free paclitaxel and 7-epipaclitaxel in dog plasma and urine by reversed-phase high-performance liquid chromatography with UV detection [J].
Fraier, D ;
Cenacchi, V ;
Frigerio, E .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :295-303
[7]   A SENSITIVE PROCEDURE FOR THE QUANTITATION OF FREE AND N-(2-HYDROXYPROPYL)METHACRYLAMIDE POLYMER-BOUND DOXORUBICIN (PK1) AND SOME OF ITS METABOLITES, 13-DIHYDRODOXORUBICIN, 13-DIHYDRODOXORUBICINONE AND DOXORUBICINONE, IN HUMAN PLASMA AND URINE BY REVERSED-PHASE HPLC WITH FLUOROMETRIC DETECTION [J].
FRAIER, D ;
FRIGERIO, E ;
PIANEZZOLA, E ;
BENEDETTI, MS ;
CASSIDY, J ;
VASEY, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (4-5) :625-633
[8]  
GIOVANELLA BC, 1991, CANCER RES, V51, P3052
[9]  
GUARINO AM, 1973, CANCER CHEMOTH REP 1, V57, P125
[10]   DETERMINATION OF CAMPTOTHECIN IN BIOLOGICAL-FLUIDS USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
LOH, JP ;
AHMED, AE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (02) :367-376