Internal calibrant in the stripping gas. An approach to calibration of membrane extraction with a sorbent interface

被引:6
作者
Liu, Xinyu [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac052181z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new technique for calibration in membrane extraction processes by adding an analytically noninterfering internal calibrant in the stripping gas is described. Membrane extraction with a sorbent interface (MESI) system was used to evaluate this method. During the membrane extraction process, the internal calibrant present in the carrier (stripping) gas and the target analyte present in the sample matrix will permeate simultaneously through the membrane in opposite directions. The changes of accumulation amounts of internal calibrant in the microtrap can be used as a means of calibration to correct the variations of extraction rate due to the variation in environmental factors, such as the sample velocity and the membrane temperature. Thus, this approach should allow for more accurate estimates of the concentrations of target analytes at various sampling or monitoring conditions during field analysis. Finally, a group of selected compounds was employed to test this calibration strategy, and the results indicated the advantages of the proposed approach for on-site analysis.
引用
收藏
页码:3001 / 3009
页数:9
相关论文
共 22 条
[1]  
[Anonymous], METHODS EXPT PHYS
[3]   INVIVO MASS-SPECTROMETRIC DETERMINATION OF ORGANIC-COMPOUNDS IN BLOOD WITH A MEMBRANE PROBE [J].
BRODBELT, JS ;
COOKS, RG ;
TOU, JC ;
KALLOS, GJ ;
DRYZGA, MD .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :454-458
[4]  
Cussler E. L., 2009, DIFFUSION MASS TRANS
[5]   Liquid membrane extraction in analytical sample preparation I.: Principles [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :318-325
[6]   Membrane-based techniques for sample enrichment [J].
Jönsson, JÅ ;
Mathiasson, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :205-225
[7]  
Kotiaho T, 2002, COMP ANAL C, V37, P531, DOI 10.1016/S0166-526X(02)80053-8
[8]   MEMBRANE MASS-SPECTROMETRY FOR THE DIRECT TRACE ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN AIR AND WATER [J].
LAPACK, MA ;
TOU, JC ;
ENKE, CG .
ANALYTICAL CHEMISTRY, 1990, 62 (13) :1265-1271
[9]   Determination of membrane permeability without calibration using solid-phase microextraction (SPME) [J].
Liu, XY ;
Pawliszyn, J .
JOURNAL OF MEMBRANE SCIENCE, 2006, 268 (01) :65-73
[10]   On-site monitoring of biogenic emissions from Eucalyptus dunnii leaves using membrane extraction with sorbent interface combined with a portable gas chromatograph system [J].
Liu, XY ;
Pawliszyn, R ;
Wang, LM ;
Pawliszyn, J .
ANALYST, 2004, 129 (01) :55-62