Measurement of FRET efficiency and ratio of donor to acceptor concentration in living cells

被引:195
作者
Chen, Huanmian
Puhl, Henry L., III
Koushik, Srinagesh V.
Vogel, Steven S.
Ikeda, Stephen R. [1 ]
机构
[1] NIAAA, Lab Mol Physiol, Sect Transmitter Signaling, NIH, Bethesda, MD 20892 USA
[2] NIAAA, Lab Mol Physiol, Sect Cellular Biophoton, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1529/biophysj.106.088773
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Measurement of fluorescence resonance energy transfer ( FRET) efficiency and the relative concentration of donor and acceptor fluorophores in living cells using the three-filter cube approach requires the determination of two constants: 1), the ratio of sensitized acceptor emission to donor fluorescence quenching ( G factor) and 2), the ratio of donor/acceptor fluorescence intensity for equimolar concentrations in the absence of FRET (k factor). We have developed a method to determine G and k that utilizes two donor-acceptor fusion proteins with differing FRET efficiencies - the value of which need not be known. We validated the method by measuring the FRET efficiency and concentration ratio of the fluorescent proteins Cerulean and Venus in mammalian cells expressing a series of fusion proteins with varying stoichiometries. The method greatly simplifies quantitative FRET measurement in living cells as it does not require cell fixation, acceptor photobleaching, protein purification, or specialized equipment for determining fluorescence spectra or lifetime.
引用
收藏
页码:L39 / L41
页数:3
相关论文
共 13 条
[1]   Evaluation of VP22 spread in tissue culture [J].
Brewis, N ;
Phelan, A ;
Webb, J ;
Drew, J ;
Elliott, G ;
O'Hare, P .
JOURNAL OF VIROLOGY, 2000, 74 (02) :1051-1056
[2]   Preassociation of calmodulin with voltage-gated Ca2+ channels revealed by FRET in single living cells [J].
Erickson, MG ;
Alseikhan, BA ;
Peterson, BZ ;
Yue, DT .
NEURON, 2001, 31 (06) :973-985
[3]   Quantitative fluorescence resonance energy transfer measurements using fluorescence microscopy [J].
Gordon, GW ;
Berry, G ;
Liang, XH ;
Levine, B ;
Herman, B .
BIOPHYSICAL JOURNAL, 1998, 74 (05) :2702-2713
[4]   Fluorescence resonance energy transfer-based stoichiometry in living cells [J].
Hoppe, A ;
Christensen, K ;
Swanson, JA .
BIOPHYSICAL JOURNAL, 2002, 83 (06) :3652-3664
[5]   Fluorescence resonance energy transfer between blue-emitting and red-shifted excitation derivatives of the green fluorescent protein [J].
Mitra, RD ;
Silva, CM ;
Youvan, DC .
GENE, 1996, 173 (01) :13-17
[6]   A variant of yellow fluorescent protein with fast and efficient maturation for cell-biological applications [J].
Nagai, T ;
Ibata, K ;
Park, ES ;
Kubota, M ;
Mikoshiba, K ;
Miyawaki, A .
NATURE BIOTECHNOLOGY, 2002, 20 (01) :87-90
[7]   Novel calibration method for flow cytometric fluorescence resonance energy transfer measurements between visible fluorescent proteins [J].
Nagy, P ;
Bene, L ;
Hyun, WC ;
Vereb, G ;
Braun, M ;
Antz, C ;
Paysan, J ;
Damjanovich, S ;
Park, JW ;
Szöllosi, J .
CYTOMETRY PART A, 2005, 67A (02) :86-96
[8]   An improved cyan fluorescent protein variant useful for FRET [J].
Rizzo, MA ;
Springer, GH ;
Granada, B ;
Piston, DW .
NATURE BIOTECHNOLOGY, 2004, 22 (04) :445-449
[9]   Quantitative multiphoton spectral imaging and its use for measuring resonance energy transfer [J].
Thaler, C ;
Koushik, SV ;
Blank, PS ;
Vogel, SS .
BIOPHYSICAL JOURNAL, 2005, 89 (04) :2736-2749
[10]   FLOW CYTOMETRIC MEASUREMENT OF FLUORESCENCE RESONANCE ENERGY-TRANSFER ON CELL-SURFACES - QUANTITATIVE-EVALUATION OF THE TRANSFER EFFICIENCY ON A CELL-BY-CELL BASIS [J].
TRON, L ;
SZOLLOSI, J ;
DAMJANOVICH, S ;
HELLIWELL, SH ;
ARNDTJOVIN, DJ ;
JOVIN, TM .
BIOPHYSICAL JOURNAL, 1984, 45 (05) :939-946