Factors affecting the accuracy of elastometric impression materials

被引:124
作者
Chen, SY
Liang, WM
Chen, FN
机构
[1] China Med Univ, Sch Dent, Taichung, Taiwan
[2] China Med Univ, Sch Publ Hlth, Taichung, Taiwan
[3] China Med Univ, Dept Social Med, Taichung, Taiwan
关键词
impression material; accuracy; storage time; filler;
D O I
10.1016/j.jdent.2004.04.002
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objectives. The purpose of this study was to evaluate the effects of (1) various impression materials, (2) different storage times and (3) the proportion of inorganic filter on the accuracy and stability of elastometric impression materials. Methods. The impression materials studied included three alginate impression materials (Algiace Z, CAVEX and Jeltrate), five commercial silicone impression materials (Aquasil, Exaflex regular type, Express, Coltex fine and Rapid liner) and two experimental silicone impression materials designed for this study (KE106A and KE106B). Impressions were made of 10 metal dies that mimicked prepared crowns. After an impression was taken, dental stone was immediately poured into the alginate impressions, white the silicone impressions was poured 30 min later and waited for 1 h for setting. The second and third stone dies were made 1 and 24h later, respectively. The diameters of the occlusal surfaces of the metal dies and stone casts were determined using photographs of the surfaces taken with a Kodak DC 290 digital. camera. The pictures were then measured using a photomicrograph digitized integration system to calculate any discrepancy. Because each impression was used to make three rounds of stone dies, two-factor mixed factorial, ANOVA was used to evaluate the effect of materials and storage time on the accuracy of the stone casts. The simple effects analysis, combined with multiple comparisons considering the per family type I error rate, was performed following confirmation that an interaction between the two factors was significant. Results. The results showed that: (1) there was a significant interaction effect between materials and storage times on the accuracy of the impressions. (2) Two addition type silicone materials, Aquasil and Exaflex, had the greatest accuracy and stability. (3) The experimental material KE106A had the least accuracy in the first and second rounds and the alginate impression material CAVEX had the least accuracy in the third round. (4) The stabilities of CAVEX and Jeltrate were the least consistent of the 10 materials and decreased significantly with storage time. (5) When the experimental material had a low proportion of filter (KE106A), there was a significantly greater dimensional discrepancy compared to the same material with a higher proportion of filter (KE106B). Conclusions. The accuracies varied among the 10 impression materials over three rounds. Of all the materials, the addition type silicone materials, Aquasil and Exaflex, had relatively greater accuracy and stability. The discrepancy of the alginate impression materials increased with storage time. The large loading of filter showed less discrepancy. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 22 条
[1]
ANUSAVICE KJ, 1996, PHILLIPS SCI DENT MA, P86
[2]
A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays [J].
Boulton, JL ;
Gage, JP ;
Vincent, PF ;
Basford, KE .
AUSTRALIAN DENTAL JOURNAL, 1996, 41 (06) :398-404
[3]
POLYVINYL SILOXANE IMPRESSION MATERIALS - A REVIEW OF PROPERTIES AND TECHNIQUES [J].
CHEE, WWL ;
DONOVAN, TE .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (05) :728-732
[4]
The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials [J].
Corso, M ;
Abanomy, A ;
Di Canzio, J ;
Zurakowski, D ;
Morgano, SM .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (06) :626-631
[5]
CRAIG RG, 1990, OPER DENT, V15, P94
[6]
Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics -: A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe-tray technique [J].
Eriksson, A ;
Öckert-Eriksson, G ;
Lockowandt, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (02) :651-660
[7]
DIMENSIONAL STABILITY OF SILICONE-BASED IMPRESSION MATERIALS [J].
FANO, V ;
GENNARI, PU ;
ORTALLI, I .
DENTAL MATERIALS, 1992, 8 (02) :105-109
[8]
Comparing the accuracy of reversible hydrocolloid and elastomeric impression materials [J].
Federick, DR ;
Caputo, A .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (02) :183-188
[9]
THE EFFECT OF TRAY SELECTION ON THE ACCURACY OF ELASTOMERIC IMPRESSION MATERIALS [J].
GORDON, GE ;
JOHNSON, GH ;
DRENNON, DG .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 63 (01) :12-15
[10]
ACCURACY OF ONE-STEP VERSUS 2-STEP PUTTY WASH ADDITION SILICONE IMPRESSION TECHNIQUE [J].
HUNG, SH ;
PURK, JH ;
TIRA, DE ;
EICK, JD .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (05) :583-589