Evaluation of Environmental Sampling Methods and Rapid Detection Assays for Recovery and Identification of Listeria spp. from Meat Processing Facilities

被引:11
作者
Kovacevic, Jovana [1 ]
Bohaychuk, Valerie M. [2 ]
Barrios, Pablo Romero [2 ]
Gensler, Gary E. [2 ]
Rolheiser, Deana L. [2 ]
McMullen, Lynn M. [1 ]
机构
[1] Univ Alberta, Dept Agr Food & Nutr Sci, Edmonton, AB T6G 2P5, Canada
[2] Alberta Agr & Rural Dev, Agri Food Lab Branch, Food Safety Div, Edmonton, AB T6H 4P2, Canada
关键词
POLYMERASE-CHAIN-REACTION; MONOCYTOGENES; SENSITIVITY; PRODUCTS; FOODS; PLANT; FISH; BEEF; BAX;
D O I
10.4315/0362-028X-72.4.696
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Studies that isolated Listeria spp. from the environment of two meat processing facilities were conducted. Samples were collected in the processing environment of the facilities with three different sampling methods (cotton swab, sterile sponge, and composite-ply tissues) to evaluate their ability to recover Listeria spp. A total of 240 samples for each sampling method were collected and tested. The cotton swab method of sampling was significantly (P < 0.01) less efficient in recovery of Listeria spp. than the sterile-sponge and composite-ply tissue methods, which were similar (P > 0.05) in their ability to recover Listeria spp. The specificity and sensitivity of four detection methods (conventional culture, Petrifilm Environmental Listeria Plates [ELP], lateral-flow immunoprecipitation [LFI], and automated PCR) were evaluated for identification of Listeria spp. Facilities were visited until a minimum of 100 positive and 100 negative samples per detection method were collected. The LFI and PCR methods were highly sensitive (95.5 and 99.1%, respectively) and specific (100%) relative to the culture method. The ELP method was significantly less efficient (P < 0.01) than LFI and PCR in detection of Listeria spp., with lower sensitivity (50.6%) and specificity (91.5%). Kappa values indicated excellent agreement of the LFl and PCR assays and moderate agreement of the ELP method to the culture method. Overall, ELP was easy to use but less efficient in detection of Listeria spp. from environmental samples, while the LFI and PCR methods were found to be excellent alternatives to culture, considering performance and time and labor inputs.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 2003, LISTERIA MONOCYTOGEN
[2]  
Autio T, 1999, APPL ENVIRON MICROB, V65, P150
[3]   PCR detection of Listeria monocytogenes:: a study of multiple factors affecting sensitivity [J].
Aznar, R ;
Alarcón, B .
JOURNAL OF APPLIED MICROBIOLOGY, 2003, 95 (05) :958-966
[4]   Rapid and specific detection of Listeria monocytogenes in smoked salmon with BAX®-PCR [J].
Becker, B ;
Jordan, S ;
Holzapfel, WH .
FOOD CONTROL, 2005, 16 (08) :717-721
[5]   Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens [J].
Bohaychuk, VM ;
Gensler, GE ;
King, RK ;
Wu, JT ;
McMullen, LM .
JOURNAL OF FOOD PROTECTION, 2005, 68 (12) :2637-2647
[6]   Estimation of diagnostic-test sensitivity and specificity through Bayesian modeling [J].
Branscum, AJ ;
Gardner, IA ;
Johnson, WO .
PREVENTIVE VETERINARY MEDICINE, 2005, 68 (2-4) :145-163
[7]   Ecology of Listeria monocytogenes in the environment of raw poultry meat and raw pork meat processing plants [J].
Chasseignaux, E ;
Gérault, P ;
Toquin, MT ;
Salvat, G ;
Colin, P ;
Ermel, G .
FEMS MICROBIOLOGY LETTERS, 2002, 210 (02) :271-275
[8]   Molecular epidemiology of Listeria monocytogenes, isolates collected from the environment, raw meat and raw products in two poultry- and pork-processing plants [J].
Chasseignaux, E ;
Toquin, MT ;
Ragimbeau, C ;
Salvat, G ;
Colin, P ;
Ermel, G .
JOURNAL OF APPLIED MICROBIOLOGY, 2001, 91 (05) :888-899
[9]   Listeria monocytogenes:: Low levels equal low risk [J].
Chen, YH ;
Ross, EH ;
Scott, VN ;
Gombas, DE .
JOURNAL OF FOOD PROTECTION, 2003, 66 (04) :570-577
[10]  
DOHOO I, 2003, VET EPIDEMIOLOGIC RE, V1, P87