Differentiation of benign and malignant breast lesions: MR imaging versus Tc-99m sestamibi scintimammography

被引:62
作者
Helbich, TH
Becherer, A
Trattnig, S
Leitha, T
Kelkar, P
Seifert, M
Gnant, M
Staudenherz, A
Rudas, M
Wolf, G
Mostbeck, GH
机构
[1] UNIV VIENNA,DEPT RADIOL,A-1090 VIENNA,AUSTRIA
[2] UNIV VIENNA,DEPT NUCL MED,A-1090 VIENNA,AUSTRIA
[3] UNIV VIENNA,DEPT SPECIAL GYNECOL,A-1090 VIENNA,AUSTRIA
[4] UNIV VIENNA,DEPT SURG,A-1090 VIENNA,AUSTRIA
[5] UNIV VIENNA,DEPT CLIN PATHOL,A-1090 VIENNA,AUSTRIA
关键词
breast neoplasms; emission CT (ECT); MR; radionuclide studies; magnetic resonance (MR); comparative studies; radionuclide imaging;
D O I
10.1148/radiology.202.2.9015068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracies of magnetic resonance (MR) imaging and scintimammography in differentiating benign from malignant breast lesions. MATERIALS AND METHODS: MR imaging was performed in 66 women with 75 lesions during intravenous administration of gadopentetate dimeglumine. Planar and single photon emission computed tomographic (SPECT) scintimammography were performed (with 740 MBq technetium-99m sestamibi administered intravenously) in all 66 patients with 75 lesions and in 64 patients with 73 lesions, respectively. MR imaging and scintimammographic studies were independently evaluated by using signal intensity measurements versus time or focal tracer uptake to differentiate benign from malignant lesions. Histopathologic proof was obtained in 63 lesions. Twelve lesions were monitored with follow-up. RESULTS: MR imaging was false-negative in one and false-positive in nine lesions. Planar scintimammography was false-negative in 10 and false-positive in six lesions. SPECT scintimammography was false-negative in four and false-positive in 10 lesions. Sensitivities and specificities for malignancy were, respectively, 96% and 82% for MR imaging, 62% and 88% for planar scintimammography, and 83% and 80% for SPECT scintimammography. CONCLUSION: Both MR imaging and scintimammography are useful in the evaluation of breast cancer. MR imaging is more sensitive and as specific as scintimammography.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 37 条
  • [1] *AMA COUNC SCI AFF, 1984, JAMA-J AM MED ASSOC, V252, P3008
  • [2] [Anonymous], ULTRASOUND DIAGNOSIS
  • [3] BEAHRS OH, 1992, MANUAL STAGING CANCE
  • [4] BECHERER A, 1995, EUR RADIOL, V5, P1399
  • [5] BREAST-TUMORS - COMPARATIVE ACCURACY OF MR-IMAGING RELATIVE TO MAMMOGRAPHY AND US FOR DEMONSTRATING EXTENT
    BOETES, C
    MUS, RDM
    HOLLAND, R
    BARENTSZ, JO
    STRIJK, SP
    WOBBES, T
    HENDRIKS, JHCL
    RUYS, SHJ
    [J]. RADIOLOGY, 1995, 197 (03) : 743 - 747
  • [6] MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE
    BOETES, C
    BARENTSZ, JO
    MUS, RD
    VANDERSLUIS, RF
    VANERNING, LJTO
    HENDRIKS, JHCL
    HOLLAND, R
    RUYS, SHJ
    [J]. RADIOLOGY, 1994, 193 (03) : 777 - 781
  • [7] DYNAMIC 3-DIMENSIONAL IMAGING WITH PARTIAL K-SPACE SAMPLING - INITIAL APPLICATION FOR GADOLINIUM-ENHANCED RATE CHARACTERIZATION OF BREAST-LESIONS
    CHENEVERT, TL
    HELVIE, MA
    AISEN, AM
    FRANCIS, IR
    ADLER, DD
    ROUBIDOUX, MA
    LONDY, FJ
    [J]. RADIOLOGY, 1995, 196 (01) : 135 - 142
  • [8] CHIU ML, 1990, J NUCL MED, V31, P1646
  • [9] CLAUSTROPHOBIA IN MRI SCANNERS
    DANTENDORFER, K
    WIMBERGER, D
    KATSCHNIG, H
    IMHOFF, H
    [J]. LANCET, 1991, 338 (8769) : 761 - 762
  • [10] TUMOR RECURRENCE VERSUS FIBROSIS IN THE IRRADIATED BREAST - DIFFERENTIATION WITH DYNAMIC GADOLINIUM-ENHANCED MR-IMAGING
    DAO, TH
    RAHMOUNI, A
    CAMPANA, F
    LAURENT, M
    ASSELAIN, B
    FOURQUET, A
    [J]. RADIOLOGY, 1993, 187 (03) : 751 - 755