Repeatability of Ocular Response Analyzer Metrics: A Gender-Based Study

被引:17
作者
David, Vinoo Philip [1 ]
Stead, Richard E. [1 ]
Vernon, Stephen A. [1 ]
机构
[1] Nottingham Univ Hosp NHS Trust, Queens Med Ctr, Dept Ophthalmol, Nottingham NG7 2UH, England
关键词
corneal hysteresis; ocular response analyzer; corneal biomechanical factors; repeatability; review; CORNEAL BIOMECHANICAL PROPERTIES; INTRAOCULAR-PRESSURE MEASUREMENT; GOLDMANN APPLANATION TONOMETRY; OPEN-ANGLE GLAUCOMA; DYNAMIC CONTOUR; REPRODUCIBILITY; HYSTERESIS; FLUCTUATION; PROGRESSION; ANESTHESIA;
D O I
10.1097/OPX.0b013e318297da45
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose. To assess the repeatability of Goldmann-correlated intraocular pressure (IOPG), corneal-compensated IOP (IOPCC), corneal hysteresis (CH), and the corneal resistance factor (CRF) obtained with the Ocular Response Analyzer (ORA) in normal eyes and to determine whether any differences in corneal biomechanical parameters or their repeatability exist between the sexes. Methods. A prospective observational study assessing 100 normal adults (50 men and 50 women; median age, 54.5 years). Comparison of ORA parameters measured in both eyes in three sets of four consecutive readings by one examiner within a 30-minute period. Results. The mean values of the ORA parameters assessed, the intraclass correlation coefficient (ICC) and the coefficient of repeatability (CR), were as follows for the right eye (n = 100): IOPG, 16.2 +/- 3.3 mm Hg (ICC, 0.96; CR, 6.37); IOPCC, 16.2 +/- 3.2 (ICC, 0.94; CR, 6.29); CRF, 10.9 +/- 1.9 (ICC, 0.91; CR, 3.62); CH, 10.6 +/- 1.7 (ICC, 0.94; CR, 3.37). The ICC between the readings was excellent (90.9) for all the ORA parameters in both sexes, with the exception of one group (female CRF ICC, 0.86). Coefficient of repeatability of the instrument satisfies the British Standards Institution criteria for repeatability. There were no significant differences between corneal biomechanical factors and IOP results for men and women. Conclusions. Corneal biomechanical parameters measured by the ORA provide repeatable results in normal eyes, with no significant difference between the sexes.
引用
收藏
页码:691 / 699
页数:9
相关论文
共 39 条
[1]
Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma [J].
Ang, Ghee Soon ;
Bochmann, Frank ;
Townend, John ;
Azuara-Blanco, Augusto .
JOURNAL OF GLAUCOMA, 2008, 17 (04) :259-262
[2]
INFLUENCE OF TOPICAL ANESTHESIA ON TONOMETRIC VALUES OF INTRAOCULAR-PRESSURE [J].
BAUDOUIN, C ;
GASTAUD, P .
OPHTHALMOLOGICA, 1994, 208 (06) :309-313
[3]
British Standards Institution (BSI), 1975, 597 BSI BS 1
[4]
Intraocular pressure fluctuation - A risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study [J].
Caprioli, Joseph ;
Coleman, Anne L. .
OPHTHALMOLOGY, 2008, 115 (07) :1123-1129
[5]
Intraocular pressure fluctuation - An independent risk factorfor glaucoma? [J].
Caprioli, Joseph .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) :1124-1125
[6]
Influence of corneal variables on accuracy of intraocular pressure measurement [J].
Damji, KF ;
Muni, RH ;
Munger, RM .
JOURNAL OF GLAUCOMA, 2003, 12 (01) :69-80
[7]
Effect of topical corneal anaesthesia on ocular response analyzer parameters: Pilot study [J].
Ehongo A. ;
De Maertelaer V. ;
Pourjavan S. .
International Ophthalmology, 2009, 29 (5) :325-328
[8]
Central corneal thickness, intraocular pressure, and degree of myopia in an adult myopic population aged 20 to 40 years in southeast Spain: determination and relationships [J].
Garcia-Medina, Manuel ;
Javier Garcia-Medina, Jose ;
Garrido-Fernandez, Pablo ;
Galvan-Espinosa, Jose ;
Martin-Molina, Jesus ;
Garcia-Maturana, Carlos ;
Perez-Pardo, Sergio ;
Dolores Pinazo-Duran, Maria .
CLINICAL OPHTHALMOLOGY, 2011, 5 :249-258
[9]
Precision of Ocular Response Analyzer [J].
Goebels, Susanne Christiane ;
Seitz, Berthold ;
Langenbucher, Achim .
CURRENT EYE RESEARCH, 2012, 37 (08) :689-693
[10]
GOLDMANN H, 1957, Ophthalmologica, V134, P221