Evaluation and a predictive model of airborne fungal concentrations in school classrooms

被引:42
作者
Bartlett, KH [1 ]
Kennedy, SM
Brauer, M
Van Netten, C
Dill, B
机构
[1] Univ British Columbia, Sch Occupat & Environm Hyg, Vancouver, BC V6T 1Z3, Canada
[2] Univ British Columbia, Dept Hlth Care & Epidemiol, Vancouver, BC V6T 1Z3, Canada
[3] Univ British Columbia, Dept Microbiol & Immunol, Vancouver, BC V6T 1Z3, Canada
关键词
bioaerosols; determinants of exposure; fungi; indoor air quality; schools;
D O I
10.1093/annhyg/meh051
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Exposure to airborne fungal products may be associated with health effects ranging from nonspecific irritation of the respiratory tract or mucus membranes to inflammation provoked by specific fungal antigens. While concentrations of airborne fungi are frequently measured in indoor air quality investigations, the significance of these measurements in the absence of visual mold colonization is unclear. This study was undertaken to evaluate concentrations of airborne fungal concentrations in school classrooms within a defined geographic location in British Columbia, Canada, and to build a model to clarify determinants of airborne fungal concentration. All elementary schools within one school district participated in the study. Classrooms examined varied by age, construction and presence or absence of mechanical ventilation. Airborne fungal propagules were collected inside classrooms and outdoors. Variables describing characteristics of the environment, buildings and occupants were measured and used to construct a predictive model of fungal concentration. The classrooms studied were not visibly contaminated by fungal growth. The data were evaluated using available guidelines. However, the published guidelines did not take into account significant aspects of the local environment. For example, there was a statistically significant effect of season on the fungal concentrations and on the proportional representation of fungal genera. Rooms ventilated by mechanical means had significantly lower geometric mean concentrations than naturally ventilated rooms. Environmental (temperature, outdoor fungal concentration), building (age) and ventilation variables accounted for 58% of the 'variation in the measured fungal concentrations. A methodology is proposed for the evaluation of airborne fungal concentration data which takes into account local environmental conditions as an aid in the evaluation of fungal bioaerosols in public buildings.
引用
收藏
页码:547 / 554
页数:8
相关论文
共 20 条
[1]   NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES [J].
ANDERSEN, AA .
JOURNAL OF BACTERIOLOGY, 1958, 76 (05) :471-484
[2]   Fungal extracellular polysaccharides, β (1→3)-glucans and culturable fungi in repeated sampling of house dust [J].
Chew, GL ;
Douwes, J ;
Doekes, G ;
Higgins, KM ;
van Strien, R ;
Spithoven, J ;
Brunekreef, B .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (03) :171-178
[3]  
Cruz A, 1997, Allergol Immunopathol (Madr), V25, P153
[4]   Influence of residential fungal contamination on peripheral blood lymphocyte populations in children [J].
Dales, R ;
Miller, D ;
White, J ;
Dulberg, C ;
Lazarovits, AI .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1998, 53 (03) :190-195
[5]   Influence of ambient fungal spores on emergency visits for asthma to a regional children's hospital [J].
Dales, RE ;
Cakmak, S ;
Burnett, RT ;
Judek, S ;
Coates, F ;
Brook, JR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (06) :2087-2090
[6]  
Dillon H.K., 1996, FIELD GUIDE DETERMIN
[7]   Building-associated pulmonary disease from exposure to Stachybotrys chartarum and Aspergillus versicolor [J].
Hodgson, MJ ;
Morey, P ;
Leung, WY ;
Morrow, L ;
Miller, D ;
Jarvis, BB ;
Robbins, H ;
Halsey, JF ;
Storey, E .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 40 (03) :241-249
[8]  
Macher J, 1999, Bioaerosols: assessment and control
[9]   The use of ergosterol to measure exposure to fungal propagules in indoor air [J].
Miller, JD ;
Young, JC .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1997, 58 (01) :39-43
[10]  
MULHAUSEN JR, 1998, STRATEGY ASSESSING M, P251