Long-life cryogenic thermometry in particle accelerators and other demanding applications

被引:2
作者
Datskov, V [1 ]
Petrova, L
Bunzarov, Z
Demko, J
Augustinowicz, S
机构
[1] Joint Inst Nucl Res, Dubna, Moscow Region, Russia
[2] Oak Ridge Natl Lab, Oak Ridge, TN USA
[3] Dynacs Co, Kennedy Space Ctr, FL USA
关键词
D O I
10.1109/77.828501
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A review of some research on the long-term stability of platinum and carbon thermometers under the working conditions of superconducting magnets for accelerators, as a function of magnetic fields, irradiation, cyclical cooling and heating, and vibration, is conducted, Results with TVO carbon-ceramic thermometers are presented for an Ii-year period,The technology for training and selecting stable thermometers that are capable of ensuring precise measurements of temperature in the 1.6-350 K range during 10-15 years in the harsh working conditions of accelerator and other installations is offered. Some recommendations for reducing the influence of the thermometer production process, thermometer mounting, and places of attachment on the accuracy of cryogenic thermometers are given.
引用
收藏
页码:1403 / 1406
页数:4
相关论文
共 17 条
[1]
BALLE C, 1996, ADV CRYOGENIC ENG B, V41
[2]
BALLE C, 1998, ADV CRYO ENG, V43
[3]
COURTS SS, 1991, APPL CRYOGENIC TECHN, V10
[4]
COURTS SS, 1994, COMMUNICATIONS
[5]
DATSKOV V, 1995, P 1995 PART ACC C IN
[6]
DATSKOV V, IBR2 ATLAS
[7]
DATSKOV VI, 1994, CRYOGENICS, V34
[8]
DATSKOV VI, 1987, COMMUNICATION JINR
[9]
DECOSMO V, 1987, REV SCI INSTRUM, V58
[10]
DEMATTIO JH, 1994, ICEC 15