Vibration characteristics of ultrasonic scalers assessed with scanning laser vibrometry

被引:32
作者
Lea, SC [1 ]
Landini, G [1 ]
Walmsley, AD [1 ]
机构
[1] Univ Birmingham, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
scanning laser vibrometry; ultrasonics; periodontology;
D O I
10.1016/S0300-5712(02)00009-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Scanning laser vibrometry is a non-invasive method of accurately measuring the vibratory characteristics of oscillating objects. The aim of this study was to observe, using a scanning laser vibrometer (SLV), the vibration patterns of dental ultrasonic scaler tips and to assess the effects of water flow rate and power setting on these patterns whilst operating the tips in an unloaded environment. Methods. A 30 kHz ultrasonic scaler (TFI-10, Dentsply) was fixed in position and a laser beam from the SLV was focused onto the tip. The laser, guided by a virtual measurement grid, was scanned over the oscillating tip surface. Scans were taken with the laser beam perpendicular to the long axis of the front face of the tip. Results. Oscillation frequencies and the displacement amplitude at the unconstrained end of the tip were measured for various power/water settings. Vibration nodal positions were recorded for the various settings and were found to occur approximately 4 turn from the free end of the tip. At low and medium power settings, tip displacement amplitude was reduced by increased water flow. At high power settings, combined with a high flow rate, the water leaves the body of the instrument as a jet. This left the tip relatively unconstrained, allowing it to oscillate at increased displacement amplitudes. Conclusions. This study shows that the SLV is able to accurately characterise the movement of oscillating ultrasonic scaler tips. The tips are affected by power setting and water flow rates. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 10 条
[1]   USE OF THE LASER DOPPLER VIBROMETER TO MEASURE THE SURFACE-TOPOGRAPHY OF MAGNETIC DISKS [J].
BOGY, DB ;
BOUCHARD, G ;
CHANG, WR ;
TALKE, FE .
WEAR, 1986, 107 (03) :227-244
[2]   A comparative in vitro study of a magnetostrictive and a piezoelectric ultrasonic scaling instrument [J].
Busslinger, A ;
Lampe, K ;
Beuchat, M ;
Lehmann, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2001, 28 (07) :642-649
[3]   FINITE-AMPLITUDE FLEXURAL VIBRATIONS AT ULTRASONIC FREQUENCIES IN METALLIC BARS [J].
CAMPOSPOZUELO, C ;
GALLEGOJUAREZ, JA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (03) :1742-1750
[4]   Working parameters of a magnetostrictive ultrasonic scaler influencing root substance removal in vitro [J].
Flemmig, TF ;
Petersilka, GJ ;
Mehl, A ;
Hickel, R ;
Klaiber, B .
JOURNAL OF PERIODONTOLOGY, 1998, 69 (05) :547-553
[5]   The effect of working parameters on root substance removal using a piezoelectric ultrasonic scaler in vitro [J].
Flemmig, TF ;
Petersilka, GJ ;
Mehl, A ;
Hickel, R ;
Klaiber, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (02) :158-163
[7]  
Muller G, 1996, ACUSTICA, V82, P657
[8]   DISPLACEMENT AMPLITUDE AS A MEASURE OF THE ACOUSTIC OUTPUT OF ULTRASONIC SCALERS [J].
WALMSLEY, AD ;
LAIRD, WRE ;
WILLIAMS, AR .
DENTAL MATERIALS, 1986, 2 (03) :97-100
[9]   INHERENT VARIABILITY OF THE PERFORMANCE OF THE ULTRASONIC DESCALER [J].
WALMSLEY, AD ;
LAIRD, WRE ;
WILLIAMS, AR .
JOURNAL OF DENTISTRY, 1986, 14 (03) :121-125
[10]   LOCALIZED FLUID FLOW MEASUREMENTS WITH AN HE-NE LASER SPECTROMETER1 ( E ) [J].
YEH, Y ;
CUMMINS, HZ .
APPLIED PHYSICS LETTERS, 1964, 4 (10) :176-&