Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography

被引:611
作者
Jenkins, C [1 ]
Bricknell, K [1 ]
Hanekom, L [1 ]
Marwick, TH [1 ]
机构
[1] Univ Queensland, Dept Med, Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
基金
英国医学研究理事会;
关键词
D O I
10.1016/j.jacc.2004.05.050
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.
引用
收藏
页码:878 / 886
页数:9
相关论文
共 15 条
[1]
STATISTICS NOTES .1. CORRELATION, REGRESSION, AND REPEATED DATA [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1994, 308 (6933) :896-896
[2]
CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[3]
MAGNETIC-RESONANCE-IMAGING COMPARED TO ECHOCARDIOGRAPHY TO ASSESS LEFT-VENTRICULAR MASS IN THE HYPERTENSIVE PATIENT [J].
BOTTINI, PB ;
CARR, AA ;
PRISANT, LM ;
FLICKINGER, FW ;
ALLISON, JD ;
GOTTDIENER, JS .
AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (03) :221-228
[4]
Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging [J].
Chuang, ML ;
Hibberd, MG ;
Salton, CJ ;
Beaudin, RA ;
Riley, MF ;
Parker, RA ;
Douglas, PS ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) :477-484
[5]
Freehand three-dimensional echocardiography for measurement of left ventricular mass: In vivo anatomic validation using explanted human hearts [J].
Gopal, AS ;
Schnellbaecher, MJ ;
Shen, ZQ ;
Akinboboye, OO ;
Sapin, PM ;
King, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :802-810
[6]
ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[7]
SHOULD ECHOCARDIOGRAPHY BE PERFORMED TO ASSESS EFFECTS OF ANTIHYPERTENSIVE THERAPY - TEST-RETEST RELIABILITY OF ECHOCARDIOGRAPHY FOR MEASUREMENT OF LEFT-VENTRICULAR MASS AND FUNCTION [J].
GOTTDIENER, JS ;
LIVENGOOD, SV ;
MEYER, PS ;
CHASE, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :424-430
[8]
Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction [J].
Hibberd, MG ;
Chuang, ML ;
Beaudin, RA ;
Riley, MF ;
Mooney, MG ;
Fearnside, JT ;
Manning, WJ ;
Douglas, PS .
AMERICAN HEART JOURNAL, 2000, 140 (03) :469-475
[9]
King D L, 1992, J Am Soc Echocardiogr, V5, P569
[10]
Noncompressibility of myocardium during systole with freehand three-dimensional echocardiography [J].
King, DL ;
Coffin, LE ;
Maurer, MS .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (12) :1503-1506