A transcutaneous hydrogen sensor: From design to application

被引:86
作者
Varghese, Oomman K. [1 ]
Yang, Xiping
Kendig, James
Paulose, Maggie
Zeng, Kefeng
Palmer, Charles
Ong, Keat Ghee
Grimes, Craig A.
机构
[1] Penn State Univ, Dept Elect Engn, Mat Res Lab 217, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Mat Sci & Engn, Mat Res Lab 217, University Pk, PA 16802 USA
[3] Sentechbiomed Corp, State Coll, PA 16803 USA
[4] Penn State Milton S Hershey Med Ctr, Div Newborn Med, Hershey, PA 17033 USA
关键词
titania nanotubes; transcutaneous; hydrogen; lactose intolerance; sensor; gas;
D O I
10.1166/sl.2006.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A transcutaneous hydrogen gas sensor of unprecedented sensitivity was fabricated and applied as a diagnostic tool for determining lactose intolerance due to lactase deficiency. The sensor, based on the use of highly-ordered titania nanotube arrays made by anodization of a 250 mu m thick titanium foil, shows a change in electrical resistance of 8.7 orders of magnitude when cycled between air and nitrogen containing 1000 ppm of hydrogen. The sensor is completely reversible with a response time of about 30 seconds. Lactose intolerance tests were conducted at the Pediatric Gastroenterology Clinic of the Penn State Children's Hospital, where the transcutaneous hydrogen gas concentration from lactose intolerant patients was monitored and compared to hydrogen levels in exhaled breath. Results indicate a direct correlation between the transcutaneous and exhaled-breath hydrogen gas concentrations.
引用
收藏
页码:120 / 128
页数:9
相关论文
共 28 条
[1]   Lactose: The milk sugar from a biotechnological perspective [J].
Adam, AC ;
Rubio-Texeira, M ;
Polaina, J .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2004, 44 (7-8) :553-557
[2]   Impact of necrotizing enterocolitis on length of stay and hospital charges in very low birth weight infants [J].
Bisquera, JA ;
Cooper, TR ;
Berseth, CL .
PEDIATRICS, 2002, 109 (03) :423-428
[3]   The effect of electrolyte composition on the fabrication of self-organized titanium oxide nanotube arrays by anodic oxidation [J].
Cai, QY ;
Paulose, M ;
Varghese, OK ;
Grimes, CA .
JOURNAL OF MATERIALS RESEARCH, 2005, 20 (01) :230-236
[4]  
Capovilla J, 2000, Crit Care Nurs Q, V23, P79
[5]   Performance of transcutaneous PCO2 and pulse oximetry monitors in newborns and infants after cardiac surgery [J].
Carter, BG ;
Wiwczaruk, D ;
Hochmann, M ;
Osborne, A ;
Henning, R .
ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (03) :260-265
[6]   A MODEL AND PROGRAM FOR STUDY OF A TOLERANCE CURVE - APPLICATION TO LACTOSE ABSORPTION TESTS [J].
CAVALLISFORZA, LT ;
MENOZZI, P ;
STRATA, A .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1983, 14 (01) :31-41
[7]  
ENGEL RR, 1973, PEDIATR RES, V7, P292
[8]  
GARSTIN WIH, 1987, J PEDIATR SURG, V22, P208
[9]  
GERLACH P, 1851, ARCH ANAT PHYSL, P431
[10]  
GODOY G, 1989, PEDIATR RES, V20, pA348