Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation

被引:30
作者
Chung, YH
Choi, Y
Cho, G
Choe, YS
Lee, KH
Kim, BT
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Nucl Med, Kangnam Ku, Seoul 135710, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
关键词
D O I
10.1088/0031-9155/49/13/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A positron emission tomograph dedicated to small animal imaging should have high spatial resolution and sensitivity, and dual layer scintillators have been developed for this purpose. In this study, simulations were performed to optimize the order and the length of each crystal of a dual layer phoswich detector, and to evaluate the possibility of measuring signals from each layer of the phoswich detector. A simulation tool GATE was used to estimate the sensitivity and resolution of a small PET scanner. The proposed scanner is based on dual layer phoswich detector modules arranged in a ring of 10 cm diameter. Each module is composed of 8 x 8 arrays of phoswich detectors consisting of LSO and LuYAP with a 2 mm x 2 mm sensitive area coupled to a Hamamatsu R7600-00-M64 PSPMT. The length of the front layer of the phoswich detector varied from 0 to 10 mm at 1 mm intervals, and the total length (LSO + LuYAP) was fixed at 20 mm. The order of the crystal layers of the phoswich detector was also changed. Radial resolutions were kept below 3.4 mm and 3.7 mm over 8 cm FOV, and sensitivities were 7.4% and 8.0% for LSO 5 mm-LuYAP 15 mm, and LuYAP 6 mm-LSO 14 mm phoswich detectors, respectively. Whereas, high and uniform resolutions were achieved by using the LSO front layer, higher sensitivities were obtained by changing the crystal order. The feasibilities for applying crystal identification methods to phoswich detectors consisting of LSO and LuYAP were investigated using simulation and experimentally derived measurements of the light outputs from each layer of the phoswich detector. In this study, the optimal order and lengths of the dual layer phoswich detector were derived in order to achieve high sensitivity and high and uniform radial resolution.
引用
收藏
页码:2881 / 2890
页数:10
相关论文
共 22 条
[1]  
Balaban R S, 2001, ILAR J, V42, P248
[2]   A DEPTH-ENCODED PET DETECTOR [J].
BARTZAKOS, P ;
THOMPSON, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :732-738
[3]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[4]  
Cherry S R, 2001, ILAR J, V42, P219
[5]   Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system [J].
Dahlbom, M ;
MacDonald, LR ;
Eriksson, L ;
Paulus, M ;
Andreaco, M ;
Casey, ME ;
Moyers, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1114-1119
[6]   Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 [J].
Heinrichs, U ;
Pietrzyk, U ;
Ziemons, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1428-1432
[7]  
JAN S, 2003, IEEE MIC REC, pM10
[8]  
KNOLL GF, 1996, TRIDN9626
[9]   Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging [J].
Lazaro, D ;
Buvat, I ;
Loudos, G ;
Strul, D ;
Santin, G ;
Giokaris, N ;
Donnarieix, D ;
Maigne, L ;
Spanoudaki, V ;
Styliaris, S ;
Staelens, S ;
Breton, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) :271-285
[10]   New inorganic scintillation materials development for medical imaging [J].
Lecoq, P ;
Korzhik, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1651-1654