Reamed versus nonreamed intramedullary nailing of lower extremity long bone fractures: A systematic overview and meta-analysis

被引:165
作者
Bhandari, M
Guyatt, GH
Tong, D
Adili, A
Shaughnessy, SG
机构
[1] McMaster Univ, Dept Clin Epidemiol & Biostat, Hamilton, ON L8N 3Z5, Canada
[2] Hamilton Civ Hosp, Res Ctr, Hamilton, ON, Canada
[3] McMaster Univ, Dept Med, Hamilton, ON L8N 3Z5, Canada
[4] McMaster Univ, Dept Orthopaed Surg, Hamilton, ON L8N 3Z5, Canada
关键词
meta-analysis; randomized trials; intramedullary nail; tibial fracture; femoral fracture;
D O I
10.1097/00005131-200001000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To determine the effect of reamed versus nonreamed intramedullary (IM) nailing of lower extremity long bone fractures on the rates of nonunion, implant failure, malunion, compartment syndrome, pulmonary embolus, and infection. Design: Quantitative systematic review of prospective, randomized controlled trials. Data Identification: MEDLINE and SCISEARCH computer searches provided lists of published randomized clinical trials from 1969 to 1998. Extensive hand searches of major orthopaedic journals, bibliographies of major orthopaedic texts, and personal files identified additional studies. Study Selection and Data Extraction: Of 676 citations initial ly identified, sixty proved potentially eligible, of which four published and five unpublished randomized trials met all eligibility criteria. Each of three investigators assessed study quality and abstracted relevant data. Results: The pooled relative risk of reamed versus nonreamed nails (nine trials, n = 646 patients) was 0.33 [95% confidence interval (CI), 0.16 to 0.68; p = 0.004]. The absolute risk difference in nonunion rates with reamed IM nailing was 7.0 percent (95% CI, 1 to 1 1 percent), Thus, one nonunion could be prevented for every fourteen patients treated with reamed IM nailing [number needed to treat (NNT) = 14.28]. The risk ratios for secondary outcome measures were: implant failure, 0.30 (95% CI, 0.16 to 0.58; p < 0.001); malunion, 1.06 (95% CI, 0.32 to 3.57); pulmonary embolus, 1.10 (95% CI, 0.26 to 4.76); compartment syndrome, 0.45 (95% CI, 0.13 to 1.56); and infection, 0.98 (95% CI, 0.21 to 4.76). Sensitivity analyses suggested that reported rates of nonunion and implant failure were higher in studies of lower quality. The type of long bone fractured (tibia or femur), the decree of soft tissue injury (open or closed), study quality, and whether a study was published or unpublished did not significantly alter the relative risk of nonunion between reamed and nonreamed IM nailing. Conclusions: There is evidence from a pooled analysis of randomized trials that reamed IM nailing of lower extremity long bone fractures significantly reduces rates of nonunion and implant failure in comparison with nonreamed nailing.
引用
收藏
页码:2 / 9
页数:8
相关论文
共 68 条