Comparison of conventional microparticulate and a monolithic reversed-phase column for high-efficiency fast liquid chromatography of basic compounds

被引:84
作者
McCalley, DV [1 ]
机构
[1] Univ W England, Sch Biomed Sci, Bristol BS16 1QY, Avon, England
关键词
monolithic columns; stationary phases; LC; pharmaceuticals;
D O I
10.1016/S0021-9673(01)01584-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of mobile phase flow on column efficiency for a neutral compound together with weak and strong bases was compared for conventional microparticulate (3/3.5 mum and 5 mum) silica RP columns and a monolithic silica RP. For benzene, the minimum plate height (H-min) at optimum flow-rate (u(opt)) for weak bases was similar for the 5 mum and the monolith phases. However, the monolith generated much flatter Van Deemter curves, such that at high flow-rate (5 ml min(-1)) the plate height was nearly 3.5 times lower on the monolith. For weak bases analysed in unbuffered mobile phases, and stronger bases with acid phosphate buffer, increased tailing was obtained on the monolith compared with the conventional phases. Nevertheless, Van Deemter plots on the monolith still showed some advantages over particulate phases, even when asymmetry factor was included in the calculation of the plate height. However, at pH 7 considerable tailing of strong bases was found using the monolith; it is not clear whether this results from unique features of the monolith structure, or whether it is due merely to usual problems of silica activity. Van Deemter plots for conventional phases may be improved considerably by operating the column at elevated temperatures. At pH 3, these improvements are influenced to a considerable extent by increases in D-m as shown by measurements of D-m using the Taylor-Aris procedure. However, at pH 7.0, improvements are much too substantial to be explainable wholly on this basis. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:51 / 64
页数:14
相关论文
共 31 条
[11]   Accuracy of empirical correlations for estimating diffusion coefficients in aqueous organic mixtures [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2530-2536
[12]  
LUBDA D, COMMUNICATION
[13]  
McCalley DV, 1999, LC GC N AM, V17, P440
[14]   Effect of organic solvent modifier and nature of solute on the performance of bonded silica reversed-phase columns for the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1996, 738 (02) :169-179
[15]   Comparative evaluation of bonded-silica reversed-phase columns for high-performance liquid chromatography using strongly basic compounds and alternative organic modifiers buffered at acid pH [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :169-178
[16]   INFLUENCE OF ANALYTE STEREOCHEMISTRY AND BASICITY ON PEAK SHAPE OF BASIC COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH REVERSED-PHASE COLUMNS, USING PYRIDINE AND ALKYL-SUBSTITUTED DERIVATIVES AS PROBE COMPOUNDS [J].
MCCALLEY, DV .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (02) :139-147
[17]   Comparison of the performance of conventional C18 phases with others of alternative functionality for the analysis of basic compounds by reversed-phase high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :23-38
[18]   Effect of temperature and flow-rate on analysis of basic compounds in high-performance liquid chromatography using a reversed-phase column [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (02) :311-321
[19]   Performance of an octadecylsilylated continuous porous silica column in polypeptide separations [J].
Minakuchi, H ;
Ishizuka, N ;
Nakanishi, K ;
Soga, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :83-90
[20]   The silanol group and its role in liquid chromatography [J].
Nawrocki, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :29-71