Bacterial viability and antibiotic susceptibility testing with SYTOX Green nucleic acid stain

被引:457
作者
Roth, BL [1 ]
Poot, M [1 ]
Yue, ST [1 ]
Millard, PJ [1 ]
机构
[1] MOL PROBES INC,EUGENE,OR 97402
关键词
D O I
10.1128/AEM.63.6.2421-2431.1997
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A fluorescent nucleic acid stain that does not penetrate living cells was used to assess the integrity of the plasma membranes of bacteria. SYTOX Green nucleic acid stain is an unsymmetrical cyanine dye with three positive charges that is completely excluded from live eukaryotic and prokaryotic cells. Binding of SYTOX Green stain to nucleic acids resulted in a >500-fold enhancement in fluorescence emission (absorption and emission maxima at 502 and 523 nm, respectively), rendering bacteria with compromised plasma membranes brightly green fluorescent. SYTOX Green stain is readily excited by the 488-nm line of the argon ion laser. The fluorescence signal from membrane-compromised bacteria labeled with SYTOX Green stain was typically >10-fold brighter than that from intact organisms. Bacterial suspensions labeled with SYTOX Green stain emitted green fluorescence in proportion to the fraction of permeabilized cells in the population, which was quantified by microscopy, fluorometry, or flow cytometry. Flow cytometric and fluorometric approaches were used to quantify the effect of beta-lactam antibiotics on the cell membrane integrity of Escherichia coli. Detection and discrimination of live and permeabilized cells labeled with SYTOX Green stain by flow cytometry were markedly improved over those by propidium iodide-based tests. These studies showed that bacterial labeling with SYTOX Green stain is an effective alternative to conventional methods for measuring bacterial viability and antibiotic susceptibility.
引用
收藏
页码:2421 / 2431
页数:11
相关论文
共 40 条
[11]  
GARNER DL, 1994, J ANDROL, V15, P620
[12]   DEVELOPMENT OF A ROBUST FLOW CYTOMETRIC ASSAY FOR DETERMINING NUMBERS OF VIABLE BACTERIA [J].
JEPRAS, RI ;
CARTER, J ;
PEARSON, SC ;
PAUL, FE ;
WILKINSON, MJ .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (07) :2696-2701
[13]   STAINING OF ESCHERICHIA-COLI FOR FLOW-CYTOMETRY - INFLUX AND EFFLUX OF ETHIDIUM-BROMIDE [J].
JERNAES, MW ;
STEEN, HB .
CYTOMETRY, 1994, 17 (04) :302-309
[14]   RELIABILITY OF CALCEIN ACETOXY METHYL-ESTER AND ETHIDIUM HOMODIMER OR PROPIDIUM IODIDE FOR VIABILITY ASSESSMENT OF MICROBES [J].
KANESHIRO, ES ;
WYDER, MA ;
WU, YP ;
CUSHION, MT .
JOURNAL OF MICROBIOLOGICAL METHODS, 1993, 17 (01) :1-16
[15]   RAPID ASSESSMENT OF BACTERIAL VIABILITY AND VITALITY BY RHODAMINE 123 AND FLOW-CYTOMETRY [J].
KAPRELYANTS, AS ;
KELL, DB .
JOURNAL OF APPLIED BACTERIOLOGY, 1992, 72 (05) :410-422
[16]   THE USE OF 5-CYANO-2,3-DITOLYL TETRAZOLIUM CHLORIDE AND FLOW-CYTOMETRY FOR THE VISUALIZATION OF RESPIRATORY ACTIVITY IN INDIVIDUAL CELLS OF MICROCOCCUS-LUTEUS [J].
KAPRELYANTS, AS ;
KELL, DB .
JOURNAL OF MICROBIOLOGICAL METHODS, 1993, 17 (02) :115-122
[17]   USE OF FLUOROCHROMES FOR DIRECT ENUMERATION OF TOTAL BACTERIA IN ENVIRONMENTAL-SAMPLES - PAST AND PRESENT [J].
KEPNER, RL ;
PRATT, JR .
MICROBIOLOGICAL REVIEWS, 1994, 58 (04) :603-615
[18]  
Langsrud S, 1996, J APPL BACTERIOL, V81, P411
[19]  
LLOYD D, 1995, FEMS MICROBIOL LETT, V133, P1
[20]  
LOPEZAMOROS R, 1995, APPL ENVIRON MICROB, V61, P2521