Automatic Distributed Voltage Control Algorithm in Smart Grids Applications

被引:168
作者
Brenna, Morris [1 ]
De Berardinis, Ettore [2 ]
Carpini, Luca Delli [3 ]
Foiadelli, Federica [1 ]
Paulon, Pietro [3 ]
Petroni, Paola [4 ]
Sapienza, Gianluca [4 ,5 ]
Scrosati, Giorgio [4 ]
Zaninelli, Dario [1 ]
机构
[1] Politecn Milan, Dept Energy, I-20156 Milan, Italy
[2] CESI SpA, I-20134 Milan, Italy
[3] Enel Distribuz SpA, Enel Distribuz Test Ctr, I-20134 Milan, Italy
[4] Enel Distribuz SpA, I-20134 Milan, Italy
[5] Politecn Milan, I-20156 Milan, Italy
关键词
Distributed generation; reactive power injection; renewable energy; sensitivity theory; smart grids; voltage regulation;
D O I
10.1109/TSG.2012.2206412
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The widespread use of distributed generation (DG), which is installed in medium-voltage distribution networks, impacts the future development of modern electrical systems that must evolve towards smart grids. A fundamental topic for smart grids is automatic distributed voltage control (ADVC). The voltage is now regulated at the MV busbar acting on the on-load tap changer of the HV/MV transformer. This method does not guarantee the correct voltage value in the network nodes when the distributed generators deliver their power. In contrast, the ADVC allows control of the voltage acting on a single generator; therefore, a better voltage profile can be obtained. In this paper, an approach based on sensitivity theory is shown to control the node voltages regulating the reactive power injected by the generators. After the theoretical analysis, a numerical example is presented to validate the theory. The proposed voltage regulation method has been developed in collaboration with Enel Distribuzione S. p. A. (the major Italian DSO), and it will be applied in the Smart Grids POI-P3 pilot project, which is financed by the Italian Economic Development Ministry. Before the real field application in the pilot project, a real-time digital simulation has been used to validate the algorithm presented. Moving in this direction, Enel Distribuzione S. p. A. built a new test center in Milan equipped with a real-time digital simulator (from RTDS Technologies).
引用
收藏
页码:877 / 885
页数:9
相关论文
共 18 条
[1]
Anderson P.M., 1999, Power system protection
[2]
Andersson G., 2008, Modeling and Analysis of Electric Power Systems ETH Zurich
[3]
[Anonymous], ELECT POWER SYSTEMS
[4]
Ayres HM, 2009, IEEE POW ENER SOC GE, P4708
[5]
New Stability Analysis for Tuning PI Controller of Power Converters in Railway Application [J].
Brenna, Morris ;
Foiadelli, Federica ;
Zaninelli, Dario .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) :533-543
[6]
Distributed reactive power generation control for voltage rise mitigation in distribution networks [J].
Carvalho, Pedro M. S. ;
Correia, Pedro F. ;
Ferreira, Luis A. F. M. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :766-772
[7]
Corsi S., 2009, 2009 IEEE BUCH POW T
[8]
Topological considerations on the symmetrical components transformation [J].
Gandelli, A ;
Leva, S ;
Morando, AP .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2000, 47 (08) :1202-1211
[9]
Grigsby LeonardL., 2006, Electric Power Generation, Transmission
[10]
STATIC OPTIMIZATION OF REACTIVE POWER SOURCES BY USE OF SENSITIVITY PARAMETERS [J].
KISHORE, A ;
HILL, EF .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (03) :1166-&