Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation

被引:81
作者
Shea, SM [1 ]
Deshpande, VS [1 ]
Chung, YC [1 ]
Li, DB [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
关键词
magnetic resonance imaging; magnetization-prepared contrast; coronary artery imaging; fast imaging; MR angiography;
D O I
10.1002/jmri.10106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of a T2-magnetization preparation scheme for improving coronary artery imaging with true fast imaging with steady-state precession (True-FISP). Materials and Methods: Simulations were performed to compare the blood-myocardium signal difference with no T2-preparation to that with various T2-preparation times (24, 40, and 60 msec) using an electrocardiogram (ECG)triggered, segmented True-FISP acquisition. Seven volunteers were imaged to evaluate the effectiveness of T2-preparation for coronary artery delineation using True-FISP and to optimize the T2-preparation time. Results: Simulations showed that T2-preparation improved the signal difference between blood and myocardium over that without T2-preparation. The optimal T2-preparation time was determined to be 40 msec. In volunteer studies, a T2-preparation time of 40 msec provided a significant improvement in contrast-to-noise ratio (CNR) between the coronary arteries and myocardium over that without T2-preparation. It also showed a significant improvement in visualizing the distal portions of the coronary arteries. Conclusion: T2-preparation improves coronary artery delineation with True-FISP. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 8 条
  • [1] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [2] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [3] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    Deshpande, VS
    Shea, SM
    Laub, G
    Simonetti, OP
    Finn, JP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 494 - 502
  • [4] MAGNETIZATION-TRANSFER AND T-2 RELAXATION COMPONENTS IN TISSUE
    HARRISON, R
    BRONSKILL, MJ
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) : 490 - 496
  • [5] MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES
    HENKELMAN, RM
    [J]. MEDICAL PHYSICS, 1985, 12 (02) : 232 - 233
  • [6] COMPENSATION FOR PULSE IMPERFECTIONS IN NMR SPIN-ECHO EXPERIMENTS
    LEVITT, MH
    FREEMAN, R
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1981, 43 (01) : 65 - 80
  • [7] BROAD-BAND HETERONUCLEAR DECOUPLING
    LEVITT, MH
    FREEMAN, R
    FRENKIEL, T
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (02) : 328 - 330
  • [8] ITERATIVE CARR-PURCELL TRAINS
    SHAKA, AJ
    RUCKER, SP
    PINES, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 77 (03): : 606 - 611