SPring-8 standard x-ray monochromators

被引:89
作者
Yabashi, M [1 ]
Yamazaki, H [1 ]
Tamasaku, K [1 ]
Goto, S [1 ]
Takeshita, K [1 ]
Mochizuki, T [1 ]
Yoneda, Y [1 ]
Furukawa, Y [1 ]
Ishikawa, T [1 ]
机构
[1] JASRI, Japan Synchroton Radiat Res Inst, SPring 8, Mikazuki, Hyogo 6795198, Japan
来源
X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS | 1999年 / 3773卷
关键词
x-ray monochromator; double-crystal geometry; fixed-exit; rotated-inclined geometry; adjustable-inclined geometry; sagittal focusing; SPring-8;
D O I
10.1117/12.370098
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most SPring-8 x-ray beamlines are installed double-crystal monochromators that are standardized. For x-ray undulator beamlines where power density of the beam are quite high, rotated-inclined double-crystal geometry is usually adopted, which enlarges the footprint of the incident beam on the crystal surface to reduce the power density. On the other hand, adjustable-inclined double-crystal geometry is adopted for bending-magnet beamlines to extend the available energy range with a limited Bragg angle range. The standardized monochromator mechanism is compatible to both of the geometries, only by changing crystal mounts. Detailed description of the monochromator mechanism is presented.
引用
收藏
页码:2 / 13
页数:12
相关论文
共 18 条
  • [1] A RAY-TRACING STUDY OF INCLINED DOUBLE-CRYSTAL MONOCHROMATORS
    BLASDELL, RC
    MACRANDER, AT
    LEE, WK
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) : 327 - 330
  • [2] MODIFICATIONS TO THE 1989 SHADOW RAY-TRACING CODE FOR GENERAL ASYMMETRIC PERFECT-CRYSTAL OPTICS
    BLASDELL, RC
    MACRANDER, AT
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) : 320 - 323
  • [3] FURUKAWA Y, 1995, SPRING 8 ANN REPORT, P191
  • [4] Standard transport channels of X-ray beamlines at SPring-8
    Goto, S
    Yabashi, M
    Ohashi, H
    Kimura, H
    Takeshita, K
    Uruga, T
    Mochizuki, T
    Kohmura, Y
    Kuroda, M
    Yamamoto, M
    Furukawa, Y
    Kamiya, N
    Ishikawa, T
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1202 - 1205
  • [5] In-vacuum undulators of SPring-8
    Hara, T
    Tanaka, T
    Tanabe, T
    Marechal, XM
    Okada, S
    Kitamura, H
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 403 - 405
  • [6] DOUBLE CRYSTAL MONOCHROMATOR FOR SYNCHROTRON RADIATION WITH DECREASED RADIATION POWER-DENSITY
    HRDY, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 459 - 460
  • [7] Water cooled first crystal as a solution for high-heat-load problem at the SPring-8 undulator beamlines
    Ishikawa, T
    Yamazaki, H
    Tamasaku, K
    Yabashi, M
    Kuroda, M
    Goto, S
    [J]. CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 : 2 - 10
  • [8] A NOVEL MONOCHROMATOR FOR HIGH HEAT LOAD SYNCHROTRON X-RAY-RADIATION
    KHOUNSARY, AM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 461 - 464
  • [9] KITAMURA H, 1996, SPRING 8 INSERTION D
  • [10] Fabrication of silicon crystals for a pin-post water-cooling system at SPring-8
    Kuroda, M
    Yamazaki, H
    Suzuki, M
    Kimura, H
    Kagaya, I
    Yamashita, C
    Ishikawa, T
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1211 - 1214