Assessment of a new transtelephonic portable spirometer

被引:23
作者
Abboud, S
Bruderman, I
机构
[1] TEL AVIV UNIV,SACKLER SCH MED,IL-69978 TEL AVIV,ISRAEL
[2] MEIR HOSP,KEFAR SAVA,ISRAEL
关键词
spirometry FVC test; lung function parameters;
D O I
10.1136/thx.51.4.407
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background - A new portable spirometer, the Spirophone, has been developed that records a subject's blow and can then transmit all the data by telephone to a receiving centre for analysis and comment. Tests of this device were undertaken to determine its accuracy and reliability. Methods - The performance of the Spirophone was tested using computer generated wave forms, by delivering blows from calibrated syringes at different flows, and by comparing subjects' blows with those recorded with a commercial spirometer. Results - Using computer generated wave forms all lung function indices were accurate to within 1% and blows delivered from calibrating syringes were accurate to within 5%. When subjects performed repeated forced vital capacity (FVC) manoeuvres there were no significant differences between lung function indices recorded with the Spirophone and with a commercial spirometer. With the Spirophone and commercial spirometer in series the FVC and forced expiratory volume in one second (FEV,) were within 5% of each other in nine out of 10 healthy subjects. Conclusion - The Spirophone recorded maximal forced expiratory manoeuvres with acceptable accuracy, reliability, and reproducibility, and this system offers the ability to monitor a patient's lung function at a centre remote from the patient.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 27 条
[1]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[2]   A SELF MANAGEMENT PLAN IN THE TREATMENT OF ADULT ASTHMA [J].
BEASLEY, R ;
CUSHLEY, M ;
HOLGATE, ST .
THORAX, 1989, 44 (03) :200-204
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   SMALL AIRWAY DIMENSIONS IN SMOKERS WITH OBSTRUCTION TO AIR-FLOW [J].
BOSKEN, CH ;
WIGGS, BR ;
PARE, PD ;
HOGG, JC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 142 (03) :563-570
[5]  
CHARLTON I, 1990, BRIT MED J, V301, P1350
[6]   POCKET-SIZED DEVICE FOR MEASURING FORCED EXPIRATORY VOLUME IN ONE 2ND AND FORCED VITAL CAPACITY [J].
CHOWIENCZYK, PJ ;
LAWSON, CP .
BRITISH MEDICAL JOURNAL, 1982, 285 (6334) :15-17
[7]  
CLAUSEN JL, 1974, MED INSTRUM, V8, P117
[8]  
EVANS R, 1987, CHEST S, V91, P65
[9]   EVALUATION OF ELECTRONIC SPIROMETERS [J].
FITZGERALD, MX ;
SMITH, AA ;
GAENSLER, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1973, 289 (24) :1283-1288
[10]  
GARDNER RM, 1980, AM REV RESPIR DIS, V121, P73