Sound localization in bilateral users of MED-EL COMBI 40/40+cochlear implants

被引:127
作者
Nopp, P [1 ]
Schleich, P [1 ]
D'Haese, P [1 ]
机构
[1] Med Elect, A-6020 Innsbruck, Austria
关键词
D O I
10.1097/01.AUD.0000130793.20444.50
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: The purpose of the study was to investigate sound localization with bilateral and unilateral cochlear implants. Design: Sound localization tests were performed on 20 bilaterally implanted MED-EL COMBI 40/40+ users. All subjects were bilaterally implanted during adolescence or later. Sound localization was tested in the frontal horizontal plane by using 9 equally spaced loudspeakers and speech-shaped noise bursts at randomized levels. Results: The group of subjects who were bilaterally deafened after 5 to 6 yr of age (18 subjects) showed a statistically significant improvement in sound localization when using both implants, compared with when using only one. The mean deviation between the presentation azimuth and the response azimuth was 16.6degrees when using both implants, which was on average 37.1degrees smaller than when using one implant only. When adjusted for the localization error that was constant across loudspeakers, the mean deviation was 15.9degrees for bilateral implant use, representing an improvement of 30.1degrees over unilateral implant use. Statistical analysis showed that in this group, performance measures were not correlated with subject details such as age at onset of deafness or duration of unilateral implant use. In contrast, subjects who were bilaterally deafened before 6 yr of age (2 subjects) did not show a benefit in sound localization from bilateral implants. Conclusions: Bilateral cochlear implants offer a substantial benefit in sound localization to late-deafened, late-implanted subjects. The very limited data from early-deafened subjects implanted at a later age could suggest that these subjects may not benefit in sound localization from bilateral cochlear implants. It is possible that early implantation for early deafened subjects might allow better acquisition of spatial hearing, thus leading to improved localization performance.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 22 条
[1]   SOUND LOCALIZATION AND SENSITIVITY TO INTERAURAL TIME DIFFERENCES IN HUMAN INFANTS [J].
ASHMEAD, DH ;
DAVIS, DL ;
WHALEN, T ;
ODOM, RD .
CHILD DEVELOPMENT, 1991, 62 (06) :1211-1226
[2]  
Blauert J., 1996, SPATIAL HEARING PSYC, DOI [https://doi.org/10.7551/mitpress/6391.001.0001, DOI 10.7551/MITPRESS/6391.001.0001, 10.7551/mitpress/6391.001.0001]
[3]  
Byrne D, 1992, J Am Acad Audiol, V3, P369
[4]  
Dermody P, 1975, BRIT J AUDIOL, V9, P93
[5]  
Durlach N. I., 1978, HDB PERCEPTION, P365, DOI DOI 10.1016/B978-0-12-161904-6.50017-8
[6]  
Fastl H., 1993, P TC HEAR AC SOC JAP, pH
[7]   Binaural cochlear implants placed during the same operation [J].
Gantz, BJ ;
Tyler, TS ;
Rubinstein, JT ;
Wolaver, A ;
Lowder, M ;
Abbas, T ;
Brown, T ;
Hughes, M ;
Preece, JP .
OTOLOGY & NEUROTOLOGY, 2002, 23 (02) :169-180
[8]   On the source-identification method [J].
Hartmann, WM ;
Rakerd, B ;
Gaalaas, JB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (06) :3546-3557
[9]   Evaluation of performance with the COMBI 40 cochlear implant in adults: A multicentric clinical study [J].
Helms, J ;
Muller, J ;
Schon, F ;
Moser, L ;
Arnold, W ;
Janssen, T ;
Ramsden, R ;
vonIlberg, C ;
Kiefer, J ;
Pfennigdorf, T ;
Gstottner, W ;
Baumgartner, W ;
Ehrenberger, K ;
Skarzynski, H ;
Ribari, O ;
Thumfart, W ;
Stephan, K ;
Mann, W ;
Heinemann, M ;
Zorowka, P ;
Lippert, KL ;
Zenner, HP ;
Bohndorf, M ;
Huttenbrink, K ;
MullerAschoff, E ;
Hofmann, G ;
Freigang, B ;
Begall, K ;
Ziese, M ;
Forgbert, O ;
Hausler, R ;
Vischer, M ;
Schlatter, T ;
Schlondorff, G ;
Korves, B ;
Doring, H ;
Gerhardt, HJ ;
Wagner, H ;
Schorn, K ;
Schilling, V ;
Baumann, U ;
Kastenbauer, E ;
Albegger, K ;
Mair, A ;
Gammert, C ;
Mathis, A ;
Streitberger, C ;
HochmairDesoyer, I .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1997, 59 (01) :23-35
[10]   Comparison of the TEMPO plus ear-level speech processor and the CISPRO plus body-worn processor in adult MED-EL cochlear implant users [J].
Helms, J ;
Müller, J ;
Schön, F ;
Winkler, F ;
Moser, L ;
Shehata-Dieler, W ;
Kastenbauer, E ;
Baumann, U ;
Rasp, G ;
Schorn, K ;
Esser, B ;
Baumgartner, W ;
Hamzavi, S ;
Gstöttner, W ;
Westhofen, M ;
Döring, W ;
Dujardin, H ;
Albegger, K ;
Mair, A ;
Zenner, HP ;
Haferkamp, C ;
Schmitz-Salue, C ;
Arold, R ;
Sesterhenn, G ;
Jahnke, V ;
Wagner, H ;
Gräbel, S ;
Bockmühl, U ;
Häusler, R ;
Vischer, M ;
Kompis, M ;
Hildmann, H ;
Radü, HJ ;
Stark, T ;
Engel, A ;
Hildmann, A ;
Streitberger, C ;
Hüttenbrink, KB ;
Müller-Aschoff, E ;
Hofmann, G ;
Seeling, K ;
Hloucal, U ;
von Ilberg, C ;
Kiefer, J ;
Pfennigdorff, T ;
Gall, V ;
Breitfuss, A ;
Stelzig, Y ;
Begall, K ;
Hey, M .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2001, 63 (01) :31-40