Temporal Control of Drug Release From Biodegradable Polymer: Multicomponent Diclofenac Sodium Releasing PLGA 80/20 Rod

被引:21
作者
Nikkola, Lila [1 ]
Viitanen, Petrus [1 ]
Ashammakhi, Nureddin [1 ]
机构
[1] Tampere Univ Technol, Dept Biomed Engn, FIN-33101 Tampere, Finland
基金
芬兰科学院;
关键词
drug delivery/release; biodegradation; NSAIDs; sustained release; bone; PEDIATRIC CRANIOFACIAL SURGERY; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; BONE-MARROW CULTURE; IN-VITRO; CORTICAL BONE; CRANIOMAXILLOFACIAL SURGERY; MECHANICAL-PROPERTIES; FIXATION DEVICES; PLATE FIXATION; SHEAR-STRENGTH;
D O I
10.1002/jbm.b.31243
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
In our previous studies we have reported on the development of diclofenac sodium (DS) releasing rods. However, their drug release profiles were unsatisfactory. To enhance the drug release properties of the implant, we have developed a system whereby various elements can be combined into one implant. Melt extruded, self-reinforced (SR), and sterilized (S) DS-containing SR-PLGA 80/20 billets were combined to produce multicomponent implants with various compositions. These components were basically heat pressed together to form multicomponent rods. Drug release from single component and multicomponent rods was defined using a UV-Vis spectrophotometer. DS was released from individual components within 82-111 days and from multicomponent rods within 50-70 days. Thermal properties were analyzed using differential scanning calorimetry (DSC). The melting temperature (T-m) of multicomponent implants was about 157 degrees C, change in heat fusion (Delta H) was 13.3 J/g, and the glass transition temperature (T-g) was 55.4 degrees C. Mechanical strength was measured for 2 weeks and it decreased from 55 to 15 MPa. In conclusion, by compression molding three components with different release rates it is possible to control the temporal release from multicomponent rods. Released DS concentrations were within range for 49-74 days depending on the fractions of individual components used. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part 13: Appl Biomater 89B: 518-526, 2009
引用
收藏
页码:518 / 526
页数:9
相关论文
共 54 条
[1]
Influence of hot pressing on the microstructure and fracture toughness of two pressable dental glass-ceramics [J].
Albakry, M ;
Guazzato, M ;
Swain, MV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 71B (01) :99-107
[2]
Developments in craniomaxillofacial surgery:: Use of self-reinforced bioabsorbable osteofixation devices [J].
Ashammakhi, N ;
Peltoniemi, H ;
Waris, E ;
Suuronen, R ;
Serlo, W ;
Kellomäki, M ;
Törmälä, P ;
Waris, T .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (01) :167-180
[3]
Drugs and fracture repair [J].
Aspenberg, P .
ACTA ORTHOPAEDICA, 2005, 76 (06) :741-748
[4]
Synthesis and study of controlled release of ibuprofen from the new acrylic type polymers [J].
Babazadeh, Mirzaagha .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2006, 316 (1-2) :68-73
[5]
LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[6]
RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[7]
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation:: a review [J].
Böstman, O ;
Pihlajamäki, H .
BIOMATERIALS, 2000, 21 (24) :2615-2621
[8]
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[9]
Characterization of microfeatures in selective laser sintered drug delivery devices [J].
Cheah, CM ;
Leong, KF ;
Chua, CK ;
Low, KH ;
Quek, HS .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) :369-383
[10]
CHIEN YW, 1987, CONTROLLED DRUG DELI, P481