Detection of microcystins with protein phosphatase inhibition assay, high-performance liquid chromatography-UV detection and enzyme-linked immunosorbent assay - Comparison of methods

被引:159
作者
Rapala, J
Erkomaa, K
Kukkonen, J
Sivonen, K
Lahti, K
机构
[1] Finnish Environm Inst, FIN-00251 Helsinki, Finland
[2] Univ Helsinki, Dept Appl Chem & Microbiol, FIN-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
microcystin; nodularin; detection; protein phosphatase; ELISA; HPLC;
D O I
10.1016/S0003-2670(02)00588-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A colorimetric protein phosphatase inhibition assay (PPI assay), a commercial enzyme-linked immunosorbent assay (ELISA) test and different HPLC methods using UV detection were compared for the detection of cyanobacterial hepatotoxins, microcystins (MCYST) and nodularin. The suitability of the methods to detect different toxin variants was evaluated by using pure toxins and laboratory cultures as well as water and bloom samples of toxic cyanobacteria. The emphasis of the study was on the analysis of polar demethyl microcystin variants that are common in nature but for which there exist no commercial standards. The IC50 values of MCYST-LR for the PPI assay and the ELISA test were 2.2-2.5 and 0.26-0.38 mug 1(-1), respectively. The most important factors that decreased toxin recovery in sample treatment were the use of C-18 cartridges and polypropylene containers. Good recoveries of toxins were obtained by using hydrophilic-lipophilic balanced (Oasis HLB, Waters) cartridges for concentrating the samples. The results obtained with the PPI assay, the ELISA test and HPLC correlated quantitatively well with the exception Of [D-Asp(3)] microcystins. Concentrations Of [D-ASp(3)]MCYST-RR measured with the PPI assay were only 5% of those obtained by the ELISA test and HPLC. Concentrations of hydrophobic microcystin variants were lower when analysed with ELISA than with the other methods. The World Health Organisation (WHO) has set a guideline value of 1 mug 1(-1) for the world-wide most common microcystin variant, MCYST-LR in drinking water. Since the quantitative ranges of the PPI assay and the ELISA test are within microcystin concentrations in natural waters, and both tests are easy to perform, they show potential for routine use in the screening and monitoring of microcystins from drinking water supplies and from recreational waters. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:213 / 231
页数:19
相关论文
共 49 条
[1]   USE OF A COLORIMETRIC PROTEIN PHOSPHATASE INHIBITION ASSAY AND ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR THE STUDY OF MICROCYSTINS AND NODULARINS [J].
AN, JS ;
CARMICHAEL, WW .
TOXICON, 1994, 32 (12) :1495-1507
[2]   Solution structure of nodularin - An inhibitor of serine/threonine-specific protein phosphatases [J].
Annila, A ;
Lehtimaki, J ;
Mattila, K ;
Eriksson, JE ;
Sivonen, K ;
Rantala, TT ;
Drakenberg, T .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (28) :16695-16702
[3]  
[Anonymous], 1998, QUAL TREAT DRINK W 2, DOI DOI 10.1007/978-3-540-68089-5_4
[4]   High grazer toxicity of [D-Asp3 (E)-Dhb7]microcystin-RR of Planktothrix rubescens as compared to different microcystins [J].
Blom, JF ;
Robinson, JA ;
Jüttner, F .
TOXICON, 2001, 39 (12) :1923-1932
[5]   IMMUNOASSAY OF HEPATOTOXIC CULTURES AND WATER BLOOMS OF CYANOBACTERIA USING MICROCYSTIS-AERUGINOSA PEPTIDE TOXIN POLYCLONAL ANTIBODIES [J].
BROOKS, WP ;
CODD, GA .
ENVIRONMENTAL TECHNOLOGY LETTERS, 1988, 9 (12) :1343-1348
[6]  
CHU FS, 1990, J ASSOC OFF ANA CHEM, V73, P451
[7]   RAPID MICROFILAMENT REORGANIZATION INDUCED IN ISOLATED RAT HEPATOCYTES BY MICROCYSTIN-LR, A CYCLIC PEPTIDE TOXIN [J].
ERIKSSON, JE ;
PAATERO, GIL ;
MERILUOTO, JAO ;
CODD, GA ;
KASS, GEN ;
NICOTERA, P ;
ORRENIUS, S .
EXPERIMENTAL CELL RESEARCH, 1989, 185 (01) :86-100
[8]  
FALCONER IR, 1981, AUST J BIOL SCI, V34, P179
[9]   CYTOSKELETAL CHANGES IN HEPATOCYTES INDUCED BY MICROCYSTIS TOXINS AND THEIR RELATION TO HYPERPHOSPHORYLATION OF CELL-PROTEINS [J].
FALCONER, IR ;
YEUNG, DSK .
CHEMICO-BIOLOGICAL INTERACTIONS, 1992, 81 (1-2) :181-196
[10]   Optimised extraction of microcystins from field samples - A comparison of different solvents and procedures [J].
Fastner, J ;
Flieger, I ;
Neumann, U .
WATER RESEARCH, 1998, 32 (10) :3177-3181