Diffusion of bioactive molecules through the walls of the medial tissue-engineered hybrid ePTFE grafts for applications in designs of vascular tissue regeneration

被引:4
作者
Noh, Insup
Choi, Yoon-Jeong
Son, Youngsook
Kim, Chun-Ho
Hong, Seung-Hwa
Hong, Choong-Man
Shin, In-Soo
Park, Sue-Nie
Park, Beom-Young
机构
[1] Seoul Natl Univ Technol, Dept Chem Engn, Seoul 139743, South Korea
[2] Korea Inst Radiol & Med Sci, Lab Tissue Engn, Seoul 139706, South Korea
[3] Korea Food & Drug Adm, Blood Prod Div, Seoul 122704, South Korea
[4] Natl Livestock Res Inst, Prod & Util Div, Suwon 441460, South Korea
关键词
diffusion; heparin; water; tissue engineered vascular grafts; hybrid ePTFE scaffold; ARTERIAL ULTRASTRUCTURE; HEPARIN TRANSPORT; POLYTETRAFLUOROETHYLENE; MECHANISMS; PROSTHESES; CONVECTION; DELIVERY; POROSITY;
D O I
10.1002/jbm.a.30872
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Strategies of better vascular tissue engineering may require delivery of soluble bioactive signals in cell culture medium to the cells in tissue-regenerating constructs. We measured the diffusivity and permeability of model tissue-engineering bioactive molecules such as water and heparin through the walls of both a hybrid ePTFE graft and a porcine carotid 3 artery, a model 3 vascular tissue. While diffusivities of H-3-water and H-heparin were measured as 3.9 x 10(-6) and 1.6 x 10(-6) cm(2)/s in the artery, respectively, under diffusional circulation of cell culture medium through the lumens of the carotid arteries, their corresponding permeabilities were 4.7 x 10(-5) and 2.0 X 10(-5) cm/s. On the other hand, diffusivities of H-3-water and H-3-heparin were also measured as 5.1 x 10(-6) and 4.7 x 10(-6) cm(2)/s, respectively, in the tissue-engineered hybrid ePTFE grafts; their corresponding permeabilities were 5.1 x 10(-5) and 3.7 x 10(-5) cm/s. The hybrid graft tissues were engineered by replacing the biodegradable, porous poly(lactide-co-glycohde) layers coated on the ePTFE surfaces with smooth muscle cell-derived tissues for 6 weeks. We analyzed the morphologies of the artery and the engineered hybrid ePTFE tissues with scanning electron microscopy and H&E stains. While the artery had its typical structure properties with layers of intima, media and adventitia, the tissue-engineered ePTFE hybrid graft had two layers of engineered tissues on the inner and outer surfaces of the ePTFE. There were no significant differences among the luminal tissue morphologies of the test samples from the effects of diffusion flow applications, with minor changes on their luminal surfaces. The results of water and heparin diffusion experiments indicated that these bioactive molecules were well transported from the cell culture medium to the tissue-engineering cells, enough to support tissue regeneration. We hope that these transport results may elucidate the transport behaviors of soluble nutrient molecules and biological signals through the vascular constructs under tissue engineering processes. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:943 / 953
页数:11
相关论文
共 21 条
[1]   Forearm arterial vein grafting:: Problems and alternative solutions [J].
Bacakoglu, A ;
Özkan, MH ;
Göktay, AY ;
Ekin, A .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2003, 31 (05) :458-465
[2]   Effect of atherosclerosis on transmural convection and arterial ultrastructure - Implications for local intravascular drug delivery [J].
Baldwin, AL ;
Wilson, LM ;
Gradus-Pizlo, I ;
Wilensky, R ;
March, K .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) :3365-3375
[3]   SMALL ARTERIAL SUBSTITUTE - EXPANDED MICROPOROUS POLYTETRAFLUOROETHYLENE - PATENCY VERSUS POROSITY [J].
CAMPBELL, CD ;
GOLDFARB, D ;
ROE, R .
ANNALS OF SURGERY, 1975, 182 (02) :138-143
[4]   Media tissue regeneration of the hybrid expanded polytetrafluoroethylene vascular graft via gelatin coating [J].
Choi, YJ ;
Noh, I .
CURRENT APPLIED PHYSICS, 2005, 5 (05) :463-467
[5]  
CHRYSANTHI W, 2005, TISSUE ENG, V10, P930
[6]   MECHANISMS OF ARTERIAL GRAFT FAILURE .2. CHRONIC ENDOTHELIAL AND SMOOTH-MUSCLE CELL-PROLIFERATION IN HEALING POLYTETRAFLUOROETHYLENE PROSTHESES [J].
CLOWES, AW ;
KIRKMAN, TR ;
CLOWES, MM .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (06) :877-884
[7]   Vascular smooth muscle cells efficiently activate a new proteinase cascade involving plasminogen and fibronectin [J].
Houard, X ;
Monnot, C ;
Dive, V ;
Corvol, P ;
Pagano, M .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2003, 88 (06) :1188-1201
[8]   Arterial ultrastructure influences transport of locally delivered drugs [J].
Hwang, CW ;
Edelman, ER .
CIRCULATION RESEARCH, 2002, 90 (07) :826-832
[9]   A novel vein graft model: adaptation to differential flow environments [J].
Jiang, ZH ;
Wu, LZ ;
Miller, BL ;
Goldman, DR ;
Fernandez, CM ;
Abouhamze, ZS ;
Ozaki, CK ;
Berceli, SA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 286 (01) :H240-H245
[10]   TISSUE ENGINEERING [J].
LANGER, R ;
VACANTI, JP .
SCIENCE, 1993, 260 (5110) :920-926