Electrocatalytic tetracycline oxidation at a mixed-valent ruthenium oxide-ruthenium cyanide-modified glassy carbon electrode and determination of tetracyclines by liquid chromatography with electrochemical detection

被引:32
作者
Loetanantawong, B
Suracheep, C
Somasundrum, M
Surareungchai, W
机构
[1] King Mongkuts Univ Technol, Sch Bioresources & Technol, Bangkok 10150, Thailand
[2] King Mongkuts Univ Technol, PDTI, Bangkok 10150, Thailand
关键词
D O I
10.1021/ac035085b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-valent films of ruthenium oxide-ruthenium Cyanide were electrodeposited onto glassy carbon and characterized for the electrocatalytic oxidation of tetracycline. The currents produced by tetracycline were higher than from previously reported electrode modifications or pretreatments. In H2SO4 pH 1.0 + 0.5 M K2SO4, the second-order rate constant for the reaction between tetracycline and the Ru(III/IV) couple of ruthenium oxide was 3 x 10(5) +/- 1 x 10(5) mol(-1) cm(3) s(-1), and the rate of charge diffusion through the films was 4.5 x 10(-7) +/- 3.5 x 10(-7) cm(2) s(-1). Reaction was localized at the film-solution interface. When used as detectors in liquid chromatography (in H3PO4 pH 2.5 + 0.1 M KH2PO4 + 20% CH3CN, E = 1.10 V vs SCE), the electrodes gave limits of detection (>3 S/N) of 0.1 ppm for tetracycline and oxytetracycline and 0.5 ppm for doxycycline and chlorotetracycline. These limits were suitable for FDA and Codex Alimentarius guidelines for tetracyclines in food. Recoveries of the four tetracyclines from sea and freshwater shrimp were in the range 73-111%, which was higher or similar to the previously reported recoveries from shrimp.
引用
收藏
页码:2266 / 2272
页数:7
相关论文
共 41 条
[21]  
CROSBY NT, 1991, DETERMINATION VET RE, P81
[22]   Liquid chromatography-(tandem) mass spectrometry of selected emerging pollutants (steroid sex hormones, drugs and alkylphenolic surfactants) in the aquatic environment [J].
de Alda, MJL ;
Díaz-Cruz, S ;
Petrovic, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :503-526
[23]  
Geankoplis C., 1993, TRANSPORT PROCESSES, P401
[24]  
*GESAMP, 1997, 65 GESAMP FAO, P40
[25]   OXIDATION OF N-NITROSAMINES AT A RUTHENIUM-BASED MODIFIED ELECTRODE IN AQUEOUS-SOLUTIONS [J].
GORSKI, W ;
COX, JA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 389 (1-2) :123-128
[26]   Chemicals and biological products used in south-east Asian shrimp farming, and their potential impact on the environment -: a review [J].
Gräslund, S ;
Bengtsson, BE .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 280 (1-3) :93-131
[27]   Determination of persistent tetracycline residues in soil fertilized with liquid manure by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry [J].
Hamscher, G ;
Sczesny, S ;
Höper, H ;
Nau, H .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1509-1518
[28]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF TETRACYCLINE ANTIBIOTICS AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
HOU, WY ;
WANG, EK .
ANALYST, 1989, 114 (06) :699-702
[29]   FLOW-INJECTION AMPEROMETRIC DETECTION BASED ON ION TRANSFER ACROSS A WATER-SOLIDIFIED NITROBENZENE INTERFACE FOR THE DETERMINATION OF TETRACYCLINE AND TERRAMYCIN [J].
JI, HM ;
WANG, EK .
ANALYST, 1988, 113 (10) :1541-1543
[30]   Evaluation of amperometric detection for the liquid-chromatographic determination of tetracycline antibiotics and their common contaminants in pharmaceutical formulations [J].
Kazemifard, AG ;
Moore, DE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (04) :689-696