Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode

被引:66
作者
Honeychurch, KC [1 ]
Hawkins, DM [1 ]
Hart, JP [1 ]
Cowell, DC [1 ]
机构
[1] Univ W England, Fac Sci Appl, Ctr Res Analyt Mat & Sensors Sci, Bristol BS16 1QY, Avon, England
关键词
screen-printed carbon electrodes; copper; differential pulse stripping voltammetry; mercury-free;
D O I
10.1016/S0039-9140(02)00060-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Screen-printed carbon electrodes (SPCEs), without chemical modification, have been investigated as disposable sensors for the measurement of trace levels of Cu2+. Cyclic voltammetry was employed to elucidate the electrochemical behaviour of Cu2+ at these electrodes in a variety of supporting electrolytes. For all of the electrolytes studied the anodic peaks, obtained on the reverse scans, showed that the Cu2+ had been deposited as a thin layer on the surface of the SPCE. The anodic peak of greatest magnitude was obtained in 0.1 M malonic acid. The possibility of determining Cu2+ at trace levels using this medium was examined by differential pulse anodic stripping voltammetry (DPASV). The effect of Bi3+, Cd2+, Fe3+, Hg-2(2+), Pb2+, Sb3+ and Zn2+ on the Cu stripping peak was examined was found to significantly effect the response gained. The sensors and under the conditions employed, only Hg-2(2+) were evaluated by carrying out Cu2+ determinations on spiked and unspiked serum and water samples. The mean recovery was found in all cases to be > 90% and the performance characteristics indicated the method holds promise for trace Cu2+ levels by employment of Hg-free SPCEs using DPASV. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:565 / 574
页数:10
相关论文
共 32 条
[11]   DETERMINATION OF IRON BY ANODIC STRIPPING VOLTAMMETRY [J].
FLORENCE, TM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 26 (2-3) :293-&
[12]   SWEDISH EXPERIENCES OF THE BAN ON PRODUCTS CONTAINING MERCURY [J].
GUSTAFSSON, E .
WATER AIR AND SOIL POLLUTION, 1995, 80 (1-4) :99-102
[13]  
HEINEMAN WR, 1984, LAB TECHNIQUES ELECT, P512
[14]  
Hodson P.V., 1979, COPPER ENV 2, P307
[15]  
Honeychurch KC, 2000, ELECTROANAL, V12, P171, DOI 10.1002/(SICI)1521-4109(200002)12:3<171::AID-ELAN171>3.0.CO
[16]  
2-Q
[17]   Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry [J].
Honeychurch, KC ;
Hart, JP ;
Cowell, DC ;
Arrigan, DWM .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) :642-652
[18]   Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry [J].
Honeychurch, KC ;
Hart, JP ;
Cowell, DC .
ANALYTICA CHIMICA ACTA, 2001, 431 (01) :89-99
[19]  
KABANOVA OL, 1970, J ANAL CHEM-USSR, V26, P94
[20]   Thick film voltammetric sensors for trace copper based on a cation-exchanger-modified surface [J].
Neuhold, CG ;
Wang, J ;
doNascimento, VB ;
Kalcher, K .
TALANTA, 1995, 42 (11) :1791-1798