Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode

被引:66
作者
Honeychurch, KC [1 ]
Hawkins, DM [1 ]
Hart, JP [1 ]
Cowell, DC [1 ]
机构
[1] Univ W England, Fac Sci Appl, Ctr Res Analyt Mat & Sensors Sci, Bristol BS16 1QY, Avon, England
关键词
screen-printed carbon electrodes; copper; differential pulse stripping voltammetry; mercury-free;
D O I
10.1016/S0039-9140(02)00060-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Screen-printed carbon electrodes (SPCEs), without chemical modification, have been investigated as disposable sensors for the measurement of trace levels of Cu2+. Cyclic voltammetry was employed to elucidate the electrochemical behaviour of Cu2+ at these electrodes in a variety of supporting electrolytes. For all of the electrolytes studied the anodic peaks, obtained on the reverse scans, showed that the Cu2+ had been deposited as a thin layer on the surface of the SPCE. The anodic peak of greatest magnitude was obtained in 0.1 M malonic acid. The possibility of determining Cu2+ at trace levels using this medium was examined by differential pulse anodic stripping voltammetry (DPASV). The effect of Bi3+, Cd2+, Fe3+, Hg-2(2+), Pb2+, Sb3+ and Zn2+ on the Cu stripping peak was examined was found to significantly effect the response gained. The sensors and under the conditions employed, only Hg-2(2+) were evaluated by carrying out Cu2+ determinations on spiked and unspiked serum and water samples. The mean recovery was found in all cases to be > 90% and the performance characteristics indicated the method holds promise for trace Cu2+ levels by employment of Hg-free SPCEs using DPASV. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:565 / 574
页数:10
相关论文
共 32 条
[21]   Characterisation of screen-printed electrodes for detection of heavy metals [J].
Palchetti, I ;
Cagnini, A ;
Mascini, M ;
Turner, APF .
MIKROCHIMICA ACTA, 1999, 131 (1-2) :65-73
[23]   Simultaneous determination of traces of iron(II) and iron(III) using differential pulse anodic stripping voltammetry in a flow-through configuration on a glassy carbon electrode [J].
van Staden, JF ;
Matoetoe, MC .
ANALYTICA CHIMICA ACTA, 1998, 376 (03) :325-330
[24]  
VYDRA F, 1976, ELECTROCHEMICAL STRI, P70
[25]   Insights into the anodic stripping voltammetric behavior of bismuth film electrodes [J].
Wang, J ;
Lu, JM ;
Anik, Ü ;
Hocevar, SB ;
Ogorevc, B .
ANALYTICA CHIMICA ACTA, 2001, 434 (01) :29-34
[26]   MERCURY-FREE DISPOSABLE LEAD SENSORS BASED ON POTENTIOMETRIC STRIPPING ANALYSIS AT GOLD-COATED SCREEN-PRINTED ELECTRODES [J].
WANG, J ;
TIAN, B .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1529-1532
[27]  
Wang J, 2001, ELECTROANAL, V13, P13, DOI 10.1002/1521-4109(200101)13:1<13::AID-ELAN13>3.0.CO
[28]  
2-F
[29]   A SELECTIVE SPOT TEST FOR COPPER [J].
WEST, PW .
INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1945, 17 (11) :740-741
[30]   COLORIMETRIC DETERMINATION OF COPPER IN WATER [J].
WEST, PW ;
COMPERE, M .
ANALYTICAL CHEMISTRY, 1949, 21 (05) :628-630