Conduction properties of the inferior vena cava tricuspid annular isthmus in patients with typical atrial flutter

被引:27
作者
Kinder, C [1 ]
Kall, J [1 ]
Kopp, D [1 ]
Rubenstein, D [1 ]
Burke, M [1 ]
Wilber, D [1 ]
机构
[1] UNIV CHICAGO,CARDIOL SECT,CHICAGO,IL 60637
关键词
atrial flutter; entrainment; slow conduction; ablation; annular isthmus;
D O I
10.1111/j.1540-8167.1997.tb00831.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conduction Properties of the Annular Isthmus. Introduction: A functional region of slow conduction located in the inferior right atrium has been postulated to be critical to the induction and maintenance of typical human atrial flutter, We reexamined the potential role of functional conduction delay in the annular isthmus between the tricuspid valve and the inferior vena cava; it is within this region that such delays have been postulated to occur, and where interruption of conduction by radiofrequency energy application has been shown to eliminate typical flutter, Methods and Results: Thirty patients with type I atrial flutter (30 counterclockwise, 14 clockwise) were studied. Counterclockwise and clockwise isthmus activation times adjacent and parallel to the tricuspid valve were measured during three conditions: (1) atrial pacing in sinus rhythm, (2) atrial flutter, and (3) entrainment of atrial flutter. During pacing in sinus rhythm at progressively shorter cycle lengths, both counterclockwise and clockwise isthmus activation times remained unchanged; decremental conduction prior to flutter induction or loss of capture was not observed. Counterclockwise isthmus activation time did not significantly differ during flutter (68 +/- 23 msec), inferolateral tricuspid annulus pacing (71 +/- 23 msec), or entrainment of flutter (72 +/- 23 msec), Similarly, clockwise isthmus activation times did not significantly differ between flutter (65 +/- 22 msec), proximal coronary sinus pacing (73 +/- 21 msec), or entrainment of flutter (64 +/- 15 msec). Conclusion: Decremental conduction is not characteristic of activation through the isthmus when activation is assessed parallel and adjacent to the tricuspid annulus. Functional slowing or conduction delay does not develop in this region during typical atrial flutter.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 25 条
[1]   CLASSIC AND CONCEALED ENTRAINMENT OF TYPICAL AND ATYPICAL ATRIAL-FLUTTER [J].
BECKMAN, K ;
HUANGTALIN ;
KRAFCHEK, J ;
WYNDHAM, CRC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :826-835
[2]   Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter [J].
Cauchemez, B ;
Haissaguerre, M ;
Fischer, B ;
Thomas, O ;
Clementy, J ;
Coumel, P .
CIRCULATION, 1996, 93 (02) :284-294
[3]   ATRIAL ENDOCARDIAL MAPPING IN THE RARE FORM OF ATRIAL-FLUTTER [J].
COSIO, FG ;
GOICOLEA, A ;
LOPEZGIL, M ;
ARRIBAS, F ;
BARROSO, JL ;
CHICOTE, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (07) :715-720
[4]   MECHANISMS OF ENTRAINMENT OF HUMAN COMMON FLUTTER STUDIED WITH MULTIPLE ENDOCARDIAL RECORDINGS [J].
COSIO, FG ;
GIL, ML ;
ARRIBAS, F ;
PALACIOS, J ;
GOICOLEA, A ;
NUNEZ, A .
CIRCULATION, 1994, 89 (05) :2117-2125
[5]   FRAGMENTED ELECTROGRAMS AND CONTINUOUS ELECTRICAL-ACTIVITY IN ATRIAL-FLUTTER [J].
COSIO, FG ;
ARRIBAS, F ;
PALACIOS, J ;
TASCON, J ;
LOPEZGIL, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (15) :1309-1314
[6]   VALIDATION OF DOUBLE-SPIKE ELECTROGRAMS AS MARKERS OF CONDUCTION DELAY OR BLOCK IN ATRIAL-FLUTTER [J].
COSIO, FG ;
ARRIBAS, F ;
BARBERO, JM ;
KALLMEYER, C ;
GOICOLEA, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (10) :775-780
[7]  
CRANEFIELD PF, 1975, CONDUCTION CARDIAC I, P153
[8]   RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES [J].
FELD, GK ;
FLECK, RP ;
CHEN, PS ;
BOYCE, K ;
BAHNSON, TD ;
STEIN, JB ;
CALISI, CM ;
IBARRA, M .
CIRCULATION, 1992, 86 (04) :1233-1240
[9]   ATRIAL REENTRY AROUND AN ANATOMIC BARRIER WITH A PARTIALLY REFRACTORY EXCITABLE GAP - A CANINE MODEL OF ATRIAL-FLUTTER [J].
FRAME, LH ;
PAGE, RL ;
HOFFMAN, BF .
CIRCULATION RESEARCH, 1986, 58 (04) :495-511
[10]   CIRCUS MOVEMENT IN THE CANINE ATRIUM AROUND THE TRICUSPID RING DURING EXPERIMENTAL ATRIAL-FLUTTER AND DURING REENTRY INVITRO [J].
FRAME, LH ;
PAGE, RL ;
BOYDEN, PA ;
FENOGLIO, JJ ;
HOFFMAN, BF .
CIRCULATION, 1987, 76 (05) :1155-1175