Irreversible optical test strip for mercury determination based on neutral ionophore

被引:23
作者
Capitán-Vallvey, LF [1 ]
Raya, CC [1 ]
López, EL [1 ]
Ramos, MDF [1 ]
机构
[1] Univ Granada, Dept Analyt Chem, Fac Sci, E-18071 Granada, Spain
关键词
mercury determination; optical test strip; neutral ionophore; water analysis;
D O I
10.1016/j.aca.2004.03.082
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A test strip for the determination of mercury in aqueous solution has been developed. It has a circular sensing zone containing all the reagents necessary to produce a selective response to mercury and formed by plasticised PVC incorporating the cation-selective neutral ionophore 1,4,7, 10-tetraazacyclododecane, the chromoionophore 9-dimethylamino-5-[4-(15-butyl-1, 13-dioxo-2,14-dioxanonadecyl)phenylimino]benzo [a]phenoxazine and tetrabutylammonium tetraphenylborate as lipophilic salt. The measurement principle is based on an ion-exchange mechanism. When the sensor is introduced for a period of time depending on the mercury content into a water sample at a pH of 4.7, there is a colour change from blue to red, making it possible to use absorbance at 670 nm as the analytical signal. All experimental variables that influence the test strip response, especially in terms of selectivity and response time, were studied. The sensor responded linearly to mercury concentration in the range 0.3 and 5.1 muM with a reproducibility in mid-calibration of 1.6% relative standard deviation (R.S.D.) for 60 min agitation. Similarly, it responded linearly to concentrations in the range 7.9-108 muM with a mid-range R.S.D. of 1.8% (for 5 min without agitation). The procedure was applied to the determination of mercury in different types of waters (tap, mineral and spring), validating the results against a reference procedure. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 30 条
[1]  
ANAND K, 1985, Patent No. 0141647
[2]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Characterisation of a transparent optical test strip for quantification of water hardness [J].
Capitán-Vallvey, LF ;
Fernández-Ramos, MD ;
Gálvez, PAD ;
Santoyo-González, F .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :139-148
[5]   Optical test strip for calcium determination based on a neutral ionophore [J].
Capitán-Vallvey, LF ;
Ramos, MDF ;
de Cienfuegos-Gálvez, PA .
ANALYTICA CHIMICA ACTA, 2002, 451 (02) :231-241
[6]   Single-use phosphorimetric sensor for the determination of nalidixic acid in human urine and milk [J].
Capitán-Vallvey, LF ;
Al-Barbarawi, OMA ;
Fernández-Ramos, MD ;
Avidad, R ;
González, VR .
ANALYST, 2000, 125 (11) :2000-2005
[7]   Determination of calcium by a single-use optical sensor [J].
Capitán-Vallvey, LF ;
de Cienfuegos-Gálvez, PA ;
Ramos, MDF ;
Avidad-Castañeda, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 71 (1-2) :140-146
[8]  
CAPITANVALLVEY LF, 2003, INTEGRATED ANAL SYST, P81
[9]  
CHARLTON SC, 1984, Patent No. 0125554
[10]   Trace determination of mercury: A review [J].
Clevenger, WL ;
Smith, BW ;
Winefordner, JD .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1997, 27 (01) :1-26