Transcatheter closure of atrial septal defect with a new flexible, self-centering device - (The STARFlex occluder)

被引:44
作者
Hausdorf, G
Kaulitz, R
Paul, T
Carminati, M
Lock, J
机构
[1] Hannover Med Sch, Dept Pediat & Pediat Cardiol 3, D-30625 Hannover, Germany
[2] Osped G Pasquinucci, Massa, Italy
[3] Harvard Univ, Childrens Hosp, Sch Med, Boston, MA 02115 USA
关键词
D O I
10.1016/S0002-9149(99)00515-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the shortterm safety and efficacy of the STARFlex Occluder for transcatheter closure of atrial septal defects with difficult anatomy. Transcatheter closure of the defect was attempted and successfully performed in 5 patients; the "stretched" defect diameter ranged from 12 to 24 mm and the implanted devices ranged from 23 to 33 mm.
引用
收藏
页码:1113 / +
页数:5
相关论文
共 21 条
[1]   Failure of devices used for closure of atrial septal defects: Mechanisms and management [J].
Agarwal, SK ;
Ghosh, PK ;
Mittal, PK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (01) :21-26
[2]   Surgical removal of atrial septal defect occlusion system-devices [J].
Bohm, J ;
Bittigau, K ;
Kohler, F ;
Baumann, G ;
Konertz, W .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (06) :869-872
[3]   EXPERIMENTAL ATRIAL SEPTAL-DEFECT CLOSURE WITH A NEW, TRANSCATHETER, SELF-CENTERING DEVICE [J].
DAS, GS ;
VOSS, G ;
JARVIS, G ;
WYCHE, K ;
GUNTHER, R ;
WILSON, RF .
CIRCULATION, 1993, 88 (04) :1754-1764
[4]   Transcatheter closure of atrial septal defects within the oval fossa: medium-term results in children using the 'ASDOS'-technique [J].
Hausdorf, G ;
Schneider, M ;
Fink, C ;
Neudorf, U ;
Fischer, G ;
Tynan, M ;
Friedli, B .
CARDIOLOGY IN THE YOUNG, 1998, 8 (04) :462-471
[5]   TRANSESOPHAGEAL ECHOCARDIOGRAPHIC GUIDANCE OF TRANSCATHETER CLOSURE OF ATRIAL SEPTAL-DEFECT [J].
HELLENBRAND, WE ;
FAHEY, JT ;
MCGOWAN, FX ;
WELTIN, GG ;
KLEINMAN, CS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :207-213
[6]   Clinical impact of transcatheter closure of secundum atrial septal detects with the double umbrella device [J].
Justo, RN ;
Nykanen, DG ;
Boutin, C ;
McCrindle, BW ;
Freedom, RM ;
Benson, LN .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (10) :889-&
[7]   Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL) [J].
Kaulitz, R ;
Paul, T ;
Hausdorf, G .
HEART, 1998, 80 (01) :54-59
[8]   MEASUREMENT OF ATRIAL SEPTAL-DEFECT DURING CARDIAC-CATHETERIZATION - EXPERIMENTAL AND CLINICAL RESULTS [J].
KING, TD ;
THOMPSON, SL ;
MILLS, NL .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (03) :537-542
[9]   SECUNDUM ATRIAL SEPTAL-DEFECT - NONOPERATIVE CLOSURE DURING CARDIAC-CATHETERIZATION [J].
KING, TD ;
THOMPSON, SL ;
STEINER, C ;
MILLS, NL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (23) :2506-2509
[10]   TRANSCATHETER CLOSURE OF ATRIAL SEPTAL-DEFECTS - EXPERIMENTAL STUDIES [J].
LOCK, JE ;
ROME, JJ ;
DAVIS, R ;
VANPRAAGH, S ;
PERRY, SB ;
VANPRAAGH, R ;
KEANE, JF .
CIRCULATION, 1989, 79 (05) :1091-1099