Pediatric cardiopulmonary bypass devices: Trends in device use for cardiopulmonary bypass and postcardiotomy support

被引:11
作者
Groom, RC [1 ]
机构
[1] Maine Med Ctr, Dept Cardiovasc Perfus, Portland, ME 04102 USA
关键词
D O I
10.1097/01.mat.0000180399.24938.a5
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Cardiopulmonary bypass (CPB) devices and techniques have continuously evolved. We have conducted surveys that chronicle the changes in CPB devices and techniques used at North American pediatric cardiac surgery centers since 1989. The aim of this article is to describe trends in cardiopulmonary bypass device use during cardiac surgery and changes in the devices used for extracorporeal life support (ECLS) following cardiac surgery for pediatric patients. The diffusion of innovation in pediatric cardiovascular surgery has not been solely driven by the availability of scientific evidence to support change but rather it has often been related to other factors that influence clinicians willingness to change including; tradition, ease of use, and cost related pressures. The current CPB systems used for cardiac surgery are more homogenous than in previous years. Most centers use a heparin coated or modified surface system comprised of a "hard shell" open venous reservoir, a roller pump, a hollow fiber membrane oxygenator, and arterial line filter. ECLS systems comprised of hollow fiber oxygenators and centrifugal pumps for are gradually replacing the classical ECLS circuit, servo regulated roller pumps and silicone rubber membranes. Nearly 40% of centers use these alternate components in their ECLS systems. Costs, utility, safety and measurable benefit to the patient should guide decisions related to device selection.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 43 条
[1]
ALLISON P L, 1990, Perfusion (London), V5, P193, DOI 10.1177/026765919000500305
[2]
Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass [J].
Brooker, RF ;
Brown, WR ;
Moody, DM ;
Hammon, JW ;
Reboussin, DM ;
Deal, DD ;
Ghazi-Birry, HS ;
Stump, DA .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1651-1655
[3]
A 10-year review of pediatric perfusion practice in North America [J].
Cecere, G ;
Groom, R ;
Forest, R ;
Quinn, R ;
Morton, J .
PERFUSION-UK, 2002, 17 (02) :83-89
[4]
CLOWES GHA, 1956, J THORAC SURG, V32, P630
[5]
COOLEY DA, 1987, TEX HEART I J, V14, P113
[6]
Techniques of paediatric modified ultrafiltration: 1996 survey results [J].
Darling, Edward ;
Nanry, Kathy ;
Shearer, Ian ;
Kaemmer, David ;
Lawson, Scott .
PERFUSION-UK, 1998, 13 (02) :93-103
[7]
DeBakey M.E., 1934, NEW ORLEANS MED SURG, V87, P386
[8]
The effect of methanol washing of plasticized polyvinyl chloride on biomaterial-contact-mediated CD11b (mac-1) expression in a rat recirculation model [J].
Gourlay, T ;
Stefanou, D ;
Taylor, KM .
ARTIFICIAL ORGANS, 2002, 26 (01) :5-9
[9]
The effect of circuit surface area on CD11b(mac-1) expression in a rat recirculation model [J].
Gourlay, T ;
Stefanou, DC ;
Asimakopoulos, G ;
Taylor, KM .
ARTIFICIAL ORGANS, 2001, 25 (06) :475-479
[10]
A model for cardiopulmonary bypass redesign [J].
Groom, RC ;
Likosky, DS ;
Forest, RJ ;
O'Connor, GT ;
Morton, JR ;
Ross, CS ;
Clark, C ;
Kramer, R .
PERFUSION-UK, 2004, 19 (04) :257-261