Determining the infiltration of outdoor particles in the indoor environment using a dynamic model

被引:90
作者
Bennett, D. H.
Koutrakis, P.
机构
[1] Univ Calif Davis, Dept Publ Hlth Sci, Davis, CA 95616 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Environm Hth Exposure, Epidemiol & Risk Program, Boston, MA 02215 USA
关键词
particle infiltration; air exchange; dynamic; penetration efficiency;
D O I
10.1016/j.jaerosci.2005.05.020
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
As people spend a significant portion of their time indoors, it is desirable to determine the fraction of outdoor particles that reach the indoor environment and the associated inter- and intra-home variability. This fraction depends on particle penetration efficiency and deposition rate. An alternative method for calculating the dynamic infiltration factor using time-dependent concentrations and air-exchange measurements is presented. We discuss the limitations of calculating the penetration rate and deposition velocity independently and find that the indoor/outdoor ratio often overestimates penetration efficiency. The dynamic infiltration factors are calculated for seven houses, for generally seven nights per house, for 17 particle size fractions. For the smallest particle size fraction (0.02-0.03 mu m), the mean infiltration factor across homes was 0.49, increasing up to 0.76 for the 0.2-0.3 mu m size fraction, and then decreasing steadily to 0.32 for the largest size fraction (4-6 mu m). The coefficients of variation between nights and homes were determined and are comparable, ranging between 0.07 and 0.18 for all the size fractions up to 1 mu m, with values up to 0.48 for larger size fractions. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:766 / 785
页数:20
相关论文
共 22 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]   Use of real-time light scattering data to estimate the contribution of infiltrated and indoor-generated particles to indoor air [J].
Allen, R ;
Larson, T ;
Sheppard, L ;
Wallace, L ;
Liu, LJS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (16) :3484-3492
[3]   Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residences [J].
Chao, CYH ;
Wan, MP ;
Cheng, ECK .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (30) :4233-4241
[4]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[5]   Is daily mortality associated specifically with fine particles? Data reconstruction and replication of analyses [J].
Klemm, RJ ;
Mason, RM ;
Heilig, CM ;
Neas, LM ;
Dockery, DW .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (07) :1215-1222
[6]  
Lai ACK, 2000, J AEROSOL SCI, V31, P463
[7]   Particle penetration through building cracks [J].
Liu, DL ;
Nazaroff, WW .
AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (07) :565-573
[8]   Modeling pollutant penetration across building envelopes [J].
Liu, DL ;
Nazaroff, WW .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (26) :4451-4462
[9]   Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior [J].
Long, CM ;
Suh, HH ;
Catalano, PJ ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (10) :2089-2099
[10]   Characterization of indoor particle sources using continuous mass and size monitors [J].
Long, CM ;
Suh, HH ;
Koutrakis, P .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (07) :1236-1250