Effect of processing and reactive dyeing on the swelling and pore structure of lyocell fibers

被引:16
作者
Kasahara, K
Sasaki, H [1 ]
Donkai, N
Takagishi, T
机构
[1] Niigata Womens Coll, Niigata 9500806, Japan
[2] Ind Res Inst Niigata Prefecture, Niigata 9540052, Japan
[3] Osaka Prefecture Univ, Grad Sch Engn, Dept Appl Mat Sci, Sakai, Osaka 5998231, Japan
关键词
D O I
10.1177/004051750407400608
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Lyocell yarns are treated with NaOH, liquid ammonia, high pressure steam, and polycarboxylic acids, then dyed with five reactive dyes. The degree of swelling and the micropore structure of the swollen samples in water are discussed in the context of the results obtained with size exclusion chromatography. The water content of the samples is also measured by centrifugal and chromatographic techniques. A good correlation is found between the values from the different techniques for all samples, except for the samples dyed with bi-functional reactive dyes. The total pore volume substantially increases with NaOH treatment and decreases with high pressure steaming. The pore size distributions for the dyed samples are essentially affected by the dyes used, i.e., depending on dye structure and reactive dye type.
引用
收藏
页码:509 / 515
页数:7
相关论文
共 19 条
[1]  
ABETA S, 1991, J SOC DYERS COLOUR, V107, P12
[2]  
BERTONIERE R, 1987, TEXT RES J, V59, P114
[3]  
BETRABET SM, 1977, J SOC DYERS COLOUR, V93, P338
[4]  
BREDERECK K, 1989, TEXTILVEREDLUNG, V24, P142
[5]   Effect of fiber swelling on the structure of lyocell fabrics [J].
Ibbett, RN ;
Hsieh, YL .
TEXTILE RESEARCH JOURNAL, 2001, 71 (02) :164-173
[6]  
Kasahara K, 2002, SEN-I GAKKAISHI, V58, P332
[7]   LIQUID-CHROMATOGRAPHY IN A CAPILLARY PACKED WITH FIBROUS CELLULOSE-ACETATE [J].
KISO, Y ;
JINNO, K ;
NAGOSHI, T .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (12) :763-764
[8]   A NEW APPROACH TO THE STUDY OF TEXTILE PROPERTIES WITH LIQUID-CHROMATOGRAPHY - COMPARISON OF VOID VOLUME AND SURFACE-AREA OF COTTON AND RAMIE USING A ROLLED FABRIC STATIONARY PHASE [J].
LADISCH, CM ;
YANG, Y ;
VELAYUDHAN, A ;
LADISCH, MR .
TEXTILE RESEARCH JOURNAL, 1992, 62 (06) :361-369
[9]   PROPERTIES AND STRUCTURE OF SOLVENT-SPUN AND VISCOSE-TYPE FIBERS IN THE SWOLLEN STATE [J].
LENZ, J ;
SCHURZ, J ;
WRENTSCHUR, E .
COLLOID AND POLYMER SCIENCE, 1993, 271 (05) :460-468
[10]   GEL PERMEATION PROPERTIES OF CELLULOSE .1. PRELIMINARY COMPARISON OF UNMODIFIED AND CROSSLINKED DECRYSTALLIZED COTTON CELLULOSE [J].
MARTIN, LF ;
ROWLAND, SP .
JOURNAL OF POLYMER SCIENCE PART A-1-POLYMER CHEMISTRY, 1967, 5 (10PA) :2563-&